6 Utility Functions (Fn
)
6-12
(4) Related Parameters
The following parameters set the program JOG operation pattern. Do not change the settings while the pro-
gram JOG operation is being executed.
Pn530
Program JOG Operation Related Switch
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
0000 to 0005
−
0000
Immediately
Setup
Pn531
Program JOG Movement Distance
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
1 to 1073741824
1 reference unit
32768
Immediately
Setup
Pn533
Program JOG Movement Speed
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
1 to 10000
1 min
-1
500
Immediately
Setup
Pn534
Program JOG Acceleration/Deceleration Time
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
2 to 10000
1 ms
100
Immediately
Setup
Pn535
Program JOG Waiting Time
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
0 to 10000
1 ms
100
Immediately
Setup
Pn536
Number of Times of Program JOG Movement
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
0 to 1000
1 time
1
Immediately
Setup
Speed
Position
Torque
Speed
Position
Torque
Speed
Position
Torque
Speed
Position
Torque
Speed
Position
Torque
Speed
Position
Torque