14
H3-10
Gain (Terminal
A2)
(Terminal A2
Gain)
0.0~
1000.0
0.1%
100.0
Y
A
A
A
A
419H
H3-11
Bias (Terminal
A2)
(Terminal A2
Bias)
-100.0
~
100.0
0.1%
0.0
Y
A
A
A
A
41AH
H3-12
Analog Input
Filter Time
Constant
(Filter Avg Time)
0.00~
2.00
0.01
sec
0.03
N
A
A
A
A
41BH
H3-13
Terminal A1/A2
Suitching
( )
0,1
1
0
0: Master frequency from terminal A1
1: Master frequency form terminal A2
*1
N
A
A
A
A
41CH
*1 When H3-13 is set to 1, the function selected by H3-19 setting works for terminal A1.
Table 4.2.2 Parameter Table (8)
P arameter Access Level
Note-2
Function
No.
Parameter Name
(Digital Operator
Display)
Setting
Range
Setting
Units
Factory
Settings
Comments
Chan
ges
on
the
Fly
V/f
V/f
w/P
G
OLV CLV
Memo
bus
Address
H4-01
Monitor Selection
(Terminal FM)
(Terminal FM Sel)
**
1~50
1
2
**Setting Range will vary based on
Control Mode (refer to attached
table).
N
A
A
A
A
41DH
H4-02
Gain (Terminal
FM)
(Terminal FM
Gain)
0.0~
1000.0
0.1%
100
Y
Q
Q
Q
Q
41EH
H4-03
Bias (Terminal
FM)
(Terminal FM
Bias)
-110.0
~
110.0
0.1%
0.0
Y
A
A
A
A
41FH
H4-04
Monitor Selection
(Terminal AM)
(Terminal AM Sel)
**
1~50
1
3
**Setting Range will vary based on
Control Mode (refer to attached
table).
N
A
A
A
A
420H
H4-05
Gain (Terminal
AM)
(Terminal AM
Gain)
0.0~
1000.0
0.1%
50
Y
Q
Q
Q
Q
421H
H4-06
Bias (Terminal
AM)
(Terminal AM
Bias)
-110.0
~
110.0
0.1%
0.0
Y
A
A
A
A
422H
H4-07
Analog Output 1
Signal Level
Selection
(AO Level
Select1)
0~2
1
0
0: 0 to +10VDC Output
1: -10VDC to +10VDC Output
2: 4 – 20 mA
N
A
A
A
A
423H
Multi Function Analog Outputs
H4-08
Analog Output 2
Signal Level
Selection
(AO Level
Select2)
0~2
1
0
0: 0 to +10VDC Output
1: -10VDC to +10VDC Output
2: 4 – 20 mA
N
A
A
A
A
424H
H5-01
Station Address
(Serial Comm
Adr)
0~20
1
1F
N
A
A
A
A
425H
H5-02
Communication
Speed Selection
(Serial Baud Rate)
0~4
1
3
0: 1200BPS 3: 9600BPS
1: 2400BPS 4: 19200BPS
2: 4800BPS
N
A
A
A
A
426H
H5-03
Communication
Parity Selection
(Serial Com Sel)
0~2
1
0
0: Parity Disabled 2: Even Number
Parity
1: Odd Number Parity
N
A
A
A
A
427H
H5-04
Stopping Method
After
Communication
Error
(Serial Fault Sel)
0~3
1
3
0: Deceleration Stop
2: Fast Stop
1: Coast to Stop 3:
Continue
Running
N
A
A
A
A
428H
H5-05
Communication
error Detection
Selection
(Scrial Flt Dtct)
0,1
1
1
0: Communication Time-Out disabled.
1: Communication Time-Out detection
enabled.
N
A
A
A
A
429H
H5-06
Send Wait Tim e
(Transmit Wait
TIM)
5~65
1ms
5
N
A
A
A
A
42AH
Memobus Communicaionts
H5-07
RTS Control
ON/OFF
(RTS Control Sel)
0,1
1
1
0: RTS Control disabled.
1: RTS Control enabled.
N
A
A
A
A
42BH
Summary of Contents for CIMR-F7Z