PRODUCT OVERVIEW
24
6SY Operation Manual
Rotation Speeds
Check instruments at regular intervals.
Redundant Throttle Mode
If there is a fault with the normal throttle or
if CAN communication is interrupted, a
redundant throttle system is provided.
In the event of a CAN open circuit or
throttle fault:
• The EMS automatically switches to the
redundant throttle located on the key
switch panel.
• The redundant throttle must be set at
zero to be activated.
• A light will illuminate on the panel
indicating the redundant throttle is
activated.
Coolant Temperature
Normal coolant temperature when the
engine is running is 70° - 90°C
(158° - 194°F).
The EMS / S6 control system has the
following alarm levels:
• If the temperature is high, 98° - 103°C,
(208° - 217°F) for one second, the S6
control will send a CAN message which
activates a warning.
• If the temperature exceeds 103°C
(217°F), a warning is activated.
• A fault code is generated in the control
unit.
After an alarm, approved values must be
registered for more than two seconds
before resetting the alarm.
Excessively high coolant temperature can
damage the engine.
If run for extended periods under an
extremely light load, the engine may have
difficulty in maintaining normal operating
temperature. However, the temperature will
rise to a normal level again when the load
on the engine is increased.
Rotation Speed
0 - 500 rpm
Prohibited engine speed,
passed through when stopping
and starting.
500 - 700 rpm
Slow idle. Engine idling is
controlled by the EMS / S6
control system.
700 - 2300 rpm
Normal operating speed. The
engine operating speed range
is controlled by the EMS / S6
control system.
2400 - 2600 rpm
Unsuitable operating speed.
2600 - 3000 rpm
Prohibited engine speed.
Summary of Contents for 6SY Series
Page 1: ...6SY series OPERATION MANUAL 6SY Operation Manual P N 0A6301 G0000 MARINE ENGINES ...
Page 34: ...PRODUCT OVERVIEW 26 6SY Operation Manual This Page Intentionally Left Blank ...
Page 54: ...BEFORE YOU OPERATE 46 6SY Operation Manual This Page Intentionally Left Blank ...
Page 120: ...LONG TERM STORAGE 114 6SY Operation Manual This Page Intentionally Left Blank ...
Page 126: ...President Yanmar Marine Int l ...
Page 127: ...President Yanmar Marine Int l ...
Page 128: ...EPA WARRANTY USA ONLY 120 6SY Operation Manual This Page Intentionally Left Blank ...