ALTERNATOR
11-16
3TNV88F Service Manual
Dynamo Wiring Diagram
DYNAMO WIRING DIAGRAM
1 – Dynamo
2 – Current limiter
3 – Key switch
4 – Charge lamp (3.4 W max.)
5 – Battery
6 – Load
Figure 11-21
OPERATION OF DYNAMO
The dynamo consists of a series of permanent magnets that rotate around a stationary stator coil. The
magnets are attached to the flywheel which is rotated via the engine cooling fan drive belt. The resultant
output is an AC (alternating current) signal. The AC is converted to DC (direct current) by the current limiter.
The current limiter outputs charging DC current to the battery.
K0002137X
1
2
3
4
5
6
3TNV88F_SVM_A4.book 16 ページ 2012年7月26日 木曜日 午後6時4分