2
Installation
2-21
10. Installing the tool flange
The tool flange can be retrofitted.
The following option parts are needed.
No.
Part No.
Q'ty
Remarks
1
KCY-M1790-000
1
Tool flange
2
91312-05014
2
Bolt
3
92A08-05308
1
Set screw
4
90K41-001490
1
Warning label
1
Turn off the controller.
2
Place a sign indicating the robot is
being adjusted.
Place a sign indicating the robot is being
adjusted, to keep others from operating the
controller and operation panel.
3
Enter the safety enclosure.
4
Install the tool flange.
Align the orientation of the tapped hole for
the tool flange set screw with that of the
width across flat part of the spline, and then
insert the tool flange all the way inside.
Tool flange (1)
Set screw (3)
Width across flat part
Degrease these
portions.
Bolt (2)
Installing the tool flange
Step 4-6
23228-HM-00
5
Install the tool flange with the bolt (2).
Secure the tool flange after it has been
inserted all the way inside.
• Tightening torque: 9Nm (92kgfcm)
Apply the grease to the bolt thinly to make
the tightening torque stable.
Degrease this portion and
affix the warning label (4).
Installing the tool flange
Step 7
23229-HM-00
6
Tighten the set screw (3).
• Tightening torque: 3.5Nm (36kgfcm)
Apply Loctite 262 (Henkel Japan) to the set
screw.
7
Affix the warning label (4).
8
Go out of the safety enclosure.
Summary of Contents for YK250XGC
Page 2: ......
Page 6: ......
Page 8: ......
Page 34: ......
Page 36: ......
Page 40: ......
Page 42: ......
Page 46: ......
Page 48: ......
Page 70: ......
Page 72: ......
Page 77: ...Chapter 4 Periodic inspecition Contents 1 List of inspection items 4 1 ...
Page 78: ......
Page 82: ......
Page 95: ......