6 - 10
–
+
ELEC
EC624000
COUPLERS AND LEADS CONNECTION
INSPECTION
1. Check:
●
Couplers and leads connection
Rust/dust/looseness/short-circuit
→
Repair or replace.
STARTER MOTOR OPERATION
1. Connect the positive battery terminal
1
and starter motor lead
2
with a jumper
lead
3
.
Not operate
→
Repair or replace the
starter motor.
WARNING
●
A wire that is used as a jumper lead must
have at least the same capacity or more
as that of the a battery lead, otherwise the
jumper lead may burn.
●
This check is likely to produce sparks,
therefore make sure nothing flammable is
in the vicinity.
STARTING CIRCUIT CUT-OFF RELAY
INSPECTION
1. Remove:
●
Starting circuit cut-off relay
2. Inspect:
●
Starting circuit cut-off relay conduct
Use 12 V battery.
Battery (+) lead
→
Sky blue lead
1
Battery (–) lead
→
Red/White lead
2
Tester (+) lead
→
Red/White lead
3
Tester (–) lead
→
Red/White lead
4
R/W
3
R/W
4
Tester selec-
tor position
Connected
to battery
Ω
×
1
Not
connected
to battery
2
4
3
1
ELECTRIC STARTING SYSTEM (TT-R125E/TT-R125LWE)