6 - 8
–
+
ELEC
ELECTRIC STARTING SYSTEM
(TT-R125E/TT-R125LWE)
STARTING CIRCUIT CUT-OFF SYSTEM
OPERATION
If the main switch is set to “ON”, the starter
motor can only operate if at least one of the
following conditions is met:
●
The transmission is in neutral (the neutral
switch is closed).
●
The clutch lever is pulled to the handlebar
(the clutch switch is closed).
The starting circuit cut-off relay prevents the
starter motor from operating when neither of
these conditions has been met. In this
instance, the starting circuit cut-off relay is
open so current cannot reach the starter
motor. When at least one of the above condi-
tions has been met the starting circuit cut-off
relay is closed and the engine can be started
by pressing the start switch.
WHEN THE TRANSMISSION IS
IN NEUTRAL
WHEN THE CLUTCH LEVER IS
PULLED TO THE HANDLEBAR
1
Battery
2
Main fuse
3
Main switch
4
Start switch
5
Starting circuit cut-off relay
6
Neutral switch
7
Clutch switch
8
Starter relay
9
Starter motor
1
2
M
3
8
5
4
6
9
7
ELECTRIC STARTING SYSTEM (TT-R125E/TT-R125LWE)