53
The Enable Telnet Server setting will enable or disable telnet access to the
Base. Please note that if this setting is set to ‘Off’ the Telnet option for servers
on the External Control Page will not function.
Selecting “Base Pairing Lock” will disable the pairing functionality from the
system’s front panel. Even if Base Pairing is not locked, the front panel
requires the password before allowing pairing of microphones.
Country/Region is required to define wireless settings in the system. You need
to select the country or region in which the system is being used.
NOTE:
Selecting a different region than the region you are using the
system in may void your right to use the system! If you are unsure
about which region to select, please contact
Yamaha
support.
For Executive Elite units acquired in Australia or Japan, the
Region is pre-selected and cannot be changed by the user.
When selecting USA / Canada as the region, for systems used in California
select “On” for that setting.
NOTE:
Not selecting that setting when in California voids your right to use
the microphone charger! If you are unsure about this setting,
please contact
Yamaha
support
.
In installations where several Executive Elite systems are in proximity, the
systems need to be synchronized to allow for best usage of the RF space and
highest number of active microphones at the same time. The “System Clock”
section sets up and controls synchronization.
Clock Source allows a user to specify which transport is used for the
synchronization. “Local” indicates that the system is a stand-alone system not
synchronizing with any other system. “Sync Bus” identifies that the 2-wire bus
is used for synchronization between different systems. AVB indicates that the
AVB network is used for synchronization between the Executive Elite systems.
The Clock Mode drop down menu is only available when “Sync Bus” is selected
as the synchronization method and allows specifying the clock source. Internal
selects this Executive Elite system as the clock source. External indicates that
a different connected Executive Elite system is the clock source.
When selecting Clock source AVB, in the AVB network control software one
Executive Elite needs to be selected as the Master Media Clock Talker (Stream
0 or Channel 0). The other Executive Elite systems that are supposed to be
synchronized to that system will need to be listeners on that Stream/Channel.