8 - 17
–
+
ELEC
ELECTRIC STARTING SYSTEM
EBS01060
YES
NO
EBS01059
YES
NO
10.Diode
• Remove the diode from the coupler.
• Connect the pocket tester (
Ω
×
1) to the
diode terminals as shown.
• Check the diode for continuity as follows.
Positive tester probe
→
green/yellow
1
Negative tester probe
→
black/yellow
2
Continuity
Positive tester probe
→
black/yellow
2
Negative tester probe
→
green/yellow
1
No
continuity
NOTE:
_
When you switch the tester’s positive and
negative probes, the readings in the above
chart will be reversed.
• Are the testing readings correct?
Replace the diode.
1
2
G
/
Y
B
/
Y
11.Wiring
• Check the entire starting system’s wiring.
Refer to “CIRCUIT DIAGRAM”.
• Is the starting system’s wiring properly
connected and without defects?
The starting system
circuit is OK.
Properly connect or
repair the starting
system’s wiring.