8-14
–
+
ELEC
SIGNAL SYSTEM
FUEL METER DOES NOT OPERATE.
Check the lighting coil.
OK
FAULTY
Replace the CDI magneto.
Check the fuel sender.
OK
FAULTY
Replace the fuel sender.
Check for voltage on the condenser coupler.
OK
OUT OF SPECIFICATION
Correct the connection and/or replace the rectifier/
regulator.
Check the condenser.
OK
OUT OF SPECIFICATION
Replace the condenser.
Check the fuel meter.
OK
DOES NOT MOVE
Replace the fuel meter.
Correct the connection for the fuel
meter system.