35
RX-V365/HTR-6230
RX-V365/HTR-6230
K 0 : 2 5 5 K 1 : 2 5 5
Display
KEY0
KEY1
23 ± 4
SCENE 1
SCENE 3
42 ± 4
SCENE 2
SCENE 4
66 ± 4
PROGRAM <
NIGHT
92 ± 4
PROGRAM >
–
120 ± 4
STRAIGHT
INPUT <
147 ± 4
TONE CONTROL
INPUT >
165 ± 4
PRESET/TUNING
PRESET/TUNING <
182 ± 4
BAND
PRESET/TUNING >
198 ± 4
A/B/C/D/E
MEMORY
217 ± 4
SPEAKERS
TUNING
255
(KEY OFF)
(KEY OFF)
1 0 . P R I : 9 0
1 0 . P R D : 0
1 0 . T H M : 2 5 5
1 0 . N O P R O T
Example
Example
Example
Example
K0/K1
K0/K1:
KEY0/KEY1 (Panel key of this unit)
When the A/D conversion value of the panel key becomes out of the specified range (standard value ±4),
normal operation will not be available.
In that case, check the constant of partial pressure resistor, solder condition, etc. with referring to the table
below.
(Reference voltage: 3.3 V=255)
10. PROTECTION HISTORY
The history of protection function is displayed.