34
RX-V365/HTR-6230
RX-V365/HTR-6230
P D : 5 8 P V : 1 1 4
T H : 6 8 P L : 2 5 5
P I : 6 D E : 2 5 5
U, C models (Reference voltage: 3.3 V=255)
R, T, K, A, B, G, E, F, L models (Reference voltage: 3.3 V=255)
(LIM: Limiter control)
(LIM: Limiter control)
During normal operation
Value for starting limiter operation Value for canceling limiter operation
PLDET
255
77
100
LIM H: 255 / L: 102
H
L
H
During normal operation
Value for starting limiter operation Value for canceling limiter operation
PLDET
255
100
131
LIM H: 255 / L: 90
H
L
H
9. A/D DATA CHECK
This menu is used to display the A/D conversion value of the microprocessor which detects panel keys of this unit and
protection functions by using the sub-menu.
When K0/K1 menu is selected, keys become non-operable due to detection of the values of all keys.
However, it is possible to advance to the next sub-menu by turning the VOLUME of this unit. When using this function,
note that turning the VOLUME more than 1 click would cause the volume value to change.
Signal processing is maintained in the status before execution.
*
The figures in the diagram are given as reference only.
PD/PV
PD:
PRD (Power amplifier DC protection detection)
The output of power amplifier DC (DC voltage) is detected.
Normal value:
35 to 81 (Reference voltage: 3.3 V=255)
PV:
PRV (Voltage protection detection)
Voltage detects: ACL, AC2, 10V, S9, +12, -12, +5V and VP
Normal value:
84 to 153 (Reference voltage: 3.3 V=255)
*
If PRD and PRV becomes out of the normal value range, the protection function works to turn off the power.
TH/PL
TH:
THM (Thermo protection detection)
The temperature of the heat sink is detected.
Normal value:
0 to 124 (Reference voltage: 3.3 V=255)
*
If THM becomes out of the normal value range, the protection function works to turn off the power.
PL:
PLDET (Power limiter detection)
The output voltage of power amplifier is detected.
PI/DE
PI:
PRI (Current protection detection)
The current of the power amplifier is detected.
Normal value:
0 to 100 (Reference voltage: 3.3 V=255)
DE:
PDET (Sub-trans power detection)
Normal value:
209 to 255 (Reference voltage: 3.3 V=255)
*
If PRI and PDET becomes out of the normal value range, the protection function works to turn off the power.
Summary of Contents for HTR-6230
Page 6: ...6 RX V365 HTR 6230 RX V365 HTR 6230 RX V365 A model RX V365 B G E F models RX V365 K model ...
Page 7: ...7 RX V365 HTR 6230 RX V365 HTR 6230 HTR 6230 U C models HTR 6230 R model RX V365 L model ...
Page 8: ...8 RX V365 HTR 6230 RX V365 HTR 6230 HTR 6230 T model HTR 6230 K model HTR 6230 G E F models ...
Page 98: ...99 RX V365 HTR 6230 RX V365 HR 6230 ...
Page 99: ...RX V365 HTR 6230 ...