AD value when the protection function is working
T H M P R T : x x x
AD value when the protection function is working
When there is a history of protection function due to abnormal voltage in the power supply section
When there is a history of protection function due to excessive heat sink temperature
Cause:
The voltage in the power supply section is abnormal.
Supplementary information:
The protection function worked due to a defect or overload in the power supply.
If the power is turned on with the abnormality unsolved, the protection function works in about 1 second to turn off
the power.
Cause:
The temperature of the heat sink is excessive.
Supplementary information:
The protection function worked due to the temperature limit being exceeded.
Causes could be poor ventilation or a defect related to the thermal sensor.
If the power is turned on with the abnormality unsolved, the protection function works in about 1 second to turn off the
power.
For detection of each protection function, refer to main menu described later.
History of protection function
When the protection function has worked, its history is stored in memory with a backup.
Even if no abnormality is noted while servicing the unit, an abnormality which has occurred previously can be defined as
long as the backup data has been stored.
The history of the protection function is cleared when self-diagnostic function is cancelled by selecting PRESET RE-
SERVED (Memory initialized) of main menu No. 13 or when the backup data is erased.
Summary of Contents for HTR-6230
Page 6: ...6 RX V365 HTR 6230 RX V365 HTR 6230 RX V365 A model RX V365 B G E F models RX V365 K model ...
Page 7: ...7 RX V365 HTR 6230 RX V365 HTR 6230 HTR 6230 U C models HTR 6230 R model RX V365 L model ...
Page 8: ...8 RX V365 HTR 6230 RX V365 HTR 6230 HTR 6230 T model HTR 6230 K model HTR 6230 G E F models ...
Page 98: ...99 RX V365 HTR 6230 RX V365 HR 6230 ...
Page 99: ...RX V365 HTR 6230 ...