7-8
SPEC
MAINTENANCE SPECIFICATIONS
Electric starting system
(EF7000E/EF7200E/EF7200DE)
Depth of insulator
mm (in)
0.4–0.8 (0.0157–0.0315)
Brush spring pressure
N (kgf, lbf)
11.73–15.35(1.20–1.57, 2.64–3.45)
Insulation resistance
M
W
More than 1.0
Brush wear limit length
mm (in)
6.0 (0.24)
Starter relay holding coil resistance
(
W
± 20 %)
1.1
Starter relay pull-in coil resistance
(
W
± 20 %)
0.5
Battery
(EF7000E/EF7200E/EF7200DE)
Voltage, capacity
12 V-12 Ah
Fuse amperage
A
20 (EF7000E/EF7200E/EF7200DE)
GENERATOR
Generator:
Type
Brushless, exciting, single-phase, synchronous
generator
Main coil AC voltage
(with the sub coil coupler connected, no load)
120 V (White–Red)
V
126.6 (EF7200DE)
240 V (White–Blue)
V
255.1 (EF7200DE)
230 V (White–Red)
V
236 (For EF7200E OCE)
220 V (White–Red)
V
236 (EF7000/EF7000E/EF7200/EF7200E)
Main coil AC voltage
(with the sub coil coupler disconnected, no
load)
120 V (White–Red)
V
26 (EF7200DE)
240 V (White–Blue)
V
51 (EF7200DE)
230 V (White–Red)
V
36 (For EF7200E OCE)
220 V (White–Red)
V
36 (EF7000/EF7000E/EF7200/EF7200E)
Sub coil AC voltage
(with the sub coil coupler disconnected, no
load)
120/240 V (Green–Green)
V
9.9/9.9 (EF7200DE)
230 V (Green–Green)
V
8.9 (For EF7200E OCE)
220 V (Green–Green)
V
8.9 (EF7000/EF7000E/EF7200/EF7200E)
Exciter field coil AC voltage (Black–White) V
17
Main coil resistance
120 V (White–Red)
(
W
± 10 %)
0.218 (EF7200DE)
240 V (White–Blue)
(
W
± 10 %)
0.507 (EF7200DE)
230 V (White–Red)
(
W
± 10 %)
0.503 (For EF7200E OCE)
220 V (White–Red)
(
W
± 10 %)
0.503 (EF7000/EF7000E/EF7200/EF7200E)