Appendix ES2 Series Servo User Manual Lite V1.0
68
Function
code
Name
Setting range
Min.
unit
Default
setting
Effective
time
Type
Mode
P18
12
Corresponding
speed information
of input position
command
-9000rpm~9000rpm
1rpm
-
N/A
Displa
y
param
eter
PST
P18
13
Position deviation
counter (32 bit)
-1073741824
~
1073741824(Encoder
minimum resolution
unit)
1P
-
N/A
Displa
y
param
eter
PST
P18
15
Input
command
pulse counter (32
bit)
-1073741824
~
1073741824(comman
d unit)
1Unit
-
N/A
Displa
y
param
eter
PST
P18
17
Feedback
pulse
counter (32 bit)
-1073741824
~
1073741824(Encoder
minimum resolution
unit)
1P
-
N/A
Displa
y
param
eter
PST
P18
19
Position deviation
counter command
unit (32 bit)
-1073741824
~
1073741824(comman
d unit)
1Unit
-
N/A
Displa
y
param
eter
PST
P18
21
Digital input signal
monitoring
-
-
-
N/A
Displa
y
param
eter
PST
P18
23
Digital output signal
monitoring
-
-
-
N/A
Displa
y
param
eter
PST
P18
25
Total power-on time
(32-bit)
0.0-429496729.6s
0.1s
-
N/A
Displa
y
param
eter
PST
P18
31
Module temperature
value
-
1°C
-
N/A
Displa
y
param
eter
PST
P18
40
Display of fault
record
0-current fault
1- the first fault
before current fault
2- the second fault
before current fault
......
9- the 9th fault
before current fault
1
0
Effective
immediate
ly
Set
when
runnin
g
PST
P18
41
error code
-
-
-
N/A
Displa
y
param
eter
PST
P18
42
Selected
fault
timestamp (32 bit)
-
0.1s
-
N/A
Displa
y
param
eter
PST
P18
44
In-time speed at
selected fault
-
1rpm
-
N/A
Displa
y
param
eter
PST
P18
45
In-time current U at
selected fault
-
0.01A
-
N/A
Displa
y
param
eter
PST
P18
46
In-time current V at
selected fault
0.01A
N/A
Displa
y
param
eter
PST