FTM-350AR/AE O
PERATING
M
ANUAL
39
F01: DUAL WATCH STOP
Function
: Selects the Dual Watch resume mode.
Available Values
: AUTO or HOLD
Default
: AUTO
AUTO:
The Dual Watch feature will stop when a signal is received on the priority
channel. When the signal drops, the Dual Watch will resume.
HOLD:
The Dual Watch feature will stop when a signal is received on the priority
channel. It will not restart automatically.
F02: SCAN DIRECTION
Function
: Select the scan start direction while initiating the scanner using the scan com-
mand by pressing the [
SCAN
] key.
Available Values
: UP START or DOWN START
Default
: UP START
F03: SCAN RESUME
Function
: Selects the scan resume mode.
Available Values
: BUSY, HOLD, TIME 1 sec, TIME 3 sec, or TIME 5 sec
Default
: TIME 5 sec
BUSY:
The scanner will hold on a signal it encounters. When the signal drops, the
scanner will resume.
HOLD:
The scanner will hold on a signal it encounters. It will not restart automati-
cally.
TIME 1 sec: The scanner will hold on a signal it encounters, and scanner will resume after
one second.
TIME 3 sec: The scanner will hold on a signal it encounters, and scanner will resume after
three seconds.
TIME 5 sec: The scanner will hold on a signal it encounters, and scanner will resume after
five seconds.
F04: SCAN STOP BEEP
Function
: Enables/Disables the scan stop beep.
Available Values
: ON or OFF
Default
: OFF
SCAN G
ROUP
M
ISCELLANEOUS
S
ETTING
(
S
ET
M
ODE
O