Page 114
FT
DX
5000 O
PERATING
M
ANUAL
You may connect an after-market transverter to the rear panel
TRV
jack. The output frequency is selectable from 14, 28,
and 50 MHz, and the output level is approximately –10 dBm (0.1 mW) at 50 Ohms.
S
ETUP
A
BOUT
THE
T
RANSVERTER
O
UTPUT
T
ERMINAL
1. Press the [
MENU
] button briefly to enter the Menu
mode.
2. Rotate the (
VFO-A
)[
SELECT
] knob to select Menu
item “
150 TUNE MY BAND
”.
3. Rotate the (
VFO-B
)[
SELECT
] knob to select the de-
sired input frequency band of the transverter in menu
item (
T14M OFF
T14M OFF
T14M OFF
T14M OFF
T14M OFF
,
T28M OFF
T28M OFF
T28M OFF
T28M OFF
T28M OFF
, or
T50M OFF
T50M OFF
T50M OFF
T50M OFF
T50M OFF
).
4. Press the [
ENT
] button (one of the [
BAND
] buttons)
to change the parameter to “ON” (the “
OFF
OFF
OFF
OFF
OFF
” notation
will change to “
ON
ON
ON
ON
ON
”).
5. Rotate the (
VFO-A
)[
SELECT
] knob to select Menu
item “
172 TGEN ETX-GND
”.
6. Rotate the (
VFO-B
)[
SELECT
] knob to set this Menu
item to “
ENABLE
ENABLE
ENABLE
ENABLE
ENABLE
” to enable the internal relay con-
nected to the rear panel
TX GND
jack.
7. Press and hold the [
MENU
] button for at least two sec-
onds to save the new setting, and exit to normal opera-
tion.
Setting the Transverter Frequency Offset
You may set up the frequency display so that it shows the
frequencies of the transverter operating band (instead of
the 28 MHz band frequencies used as the “IF” on your
FT
DX
5000
).
Example
: Setting up the
FT
DX
5000
display for use with a
144 MHz Transverter
1. Connect the 144 MHz transverter to the
FT
DX
5000
.
2. Press the [
MENU
] button briefly, to enter the Menu
mode.
3. Rotate the (
VFO-A
)[
SELECT
] knob to select the
Menu item which designates the input frequency band
from the transverter (
040 GENE TRV 14M
,
041
GENE TRV 28M
, or
042 GENE TRV 50M
).
4. Rotate the (
VFO-B
)[
SELECT
] knob to select
“
44MHz
44MHz
44MHz
44MHz
44MHz
” on the display.
5. Press and hold the [
MENU
] button in for at least two
seconds to save the new setting and exit.
The “100 MHz” digit of the frequency is not displayed,
so when you are operating on 2 meters and see “45
MHz” on the frequency readout, this indicates “145
MHz” instead.
A
DVICE
:
With the setup described above, tuning the actual operat-
ing range of the
FT
DX
5000
will correspond to transverter
operating frequency of 144-145 MHz, with “44-45” being
displayed on the front panel of the transceiver.
(VFO-B)[SELECT] Knob
[MENU] Button
(VFO-A)[SELECT] Knob
[ENT] Button
Summary of Contents for FTDX5000 CAT BOOK
Page 7: ...Page 5 FTDX5000 OPERATING MANUAL NOTE...
Page 87: ...Page 85 FTDX5000 OPERATING MANUAL NOTE...
Page 115: ...Page 113 FTDX5000 OPERATING MANUAL NOTE...
Page 139: ...Page 137 FTDX5000 OPERATING MANUAL MENU MODE NOTE...
Page 143: ...Page 141 FTDX5000 OPERATING MANUAL NOTE...