Page 30
FT
DX
9000MP O
PERATION
M
ANUAL
VDD
TEMP
SWR
BIAS
CF Card Slot
This slot accepts the supplied Compact Flash (CF)
Card, which allows storage, transfer, and recall of
transceiver configuration data and operator prefer-
ences, along with Log Book data, etc. When the CF
Card is successfully inserted, the Red LED by the slot
will light up.
To remove the card out from slot, press the small push-
button at the right hand side of the slot.
Advice
:
If you get the “
PLEASE CHECK A DISK
” error mes-
sage to the right of the MEM CARD indication on the
External Display, check the position of the CF Card
in the slot for proper alignment.
LCD Display
This 1.8 inch LCD display is used for viewing the
status of the Main (VFO-A) and Sub (VFO-B) bands,
and it indicates the Menu listing.
VDD/BIAS Meter
You may observe the Drain Voltage on the final am-
plifier FETs, using this meter. As well, the current Bias
Level being utilized may be observed. Press the [
VDD
]
(#
below) or [
BIAS
] (#
below) switch to select
the desired information.
VDD Switch
Pressing this switch enables display of the final am-
plifier FET Drain Voltage on the [
VDD/BIAS
] meter
(#
above); a red LED will light up to confirm your
selection. The display range is 0 ~ 60 Volts, and a
reading of 50 Volts is normal during transmission.
BIAS Switch
Pressing this switch enables display of the final am-
plifier FET Bias Level currently in use; a red LED
will light up to confirm your selection.
During Class-A operation, the Bias Level will indi-
cate “0%” during Class AB operation, and “100%”
during Class A. Because the power output is fixed
when the “Class A” mode has been engaged, you may
adjust the Bias Level, according to the measured tem-
perature, anywhere between Class AB and Class A,
without having to worry about the drive level being
applied to your linear amplifier.
TEMP/SWR Meter
This meter allows monitoring of the heat sink tem-
perature or the SWR as measured at the rear-panel
Antenna jack.
Press the [
TEMP
] (#
below) or [
SWR
] (#
be-
low) switch to select the desired display function.
TEMP Switch
Pressing this switch enables monitoring of the heat
sink temperature; a red LED will light up to confirm
your selection.
The measurement range for the temperature display is
0 °C ~ 100 °C, and there are four stages of cooling fan
speed that will,, progressively, increase the air flow if
the temperature rises to near the “red zone” (80 °C or
higher). Because of the advanced cooling system, there
should never be a circumstance where the tempera-
ture will rise this high, but if you are operating in a hot
environment, in Class A, and are making long trans-
missions, you may wish to reduce the Bias Level closer
to Class AB to reduce the heat dissipation associated
with Class A operation.
FFFFF
RRRRRONT
ONT
ONT
ONT
ONT
P P P P P
ANEL
ANEL
ANEL
ANEL
ANEL
C C C C C
ONTR
ONTR
ONTR
ONTR
ONTROLS
OLS
OLS
OLS
OLS
Summary of Contents for FTDX-9000MP
Page 1: ...FTDX 9000MP Operation Manual...
Page 2: ......
Page 125: ...Page 123 FT DX 9000MP OPERATION MANUAL N N N N NO O O O OTE TE TE TE TE...
Page 166: ...Page 164 FT DX 9000MP OPERATION MANUAL N N N N NO O O O OTE TE TE TE TE...
Page 171: ...Page 169 FT DX 9000MP OPERATION MANUAL N N N N NO O O O OTE TE TE TE TE...
Page 175: ...Page 173 FT DX 9000MP OPERATION MANUAL N N N N NO O O O OTE TE TE TE TE...
Page 178: ...Page 176 FT DX 9000MP OPERATION MANUAL N N N N NO O O O OTE TE TE TE TE...