68
FT-7800R O
PERATING
M
ANUAL
Menu #1
[
APO
]
Function
: Selects the Automatic Power Off time (time before power goes off).
Available Values
: OFF/0.5 H - 12.0 H in 0.5 hour multiples.
Default
: OFF (Disables the APO feature)
Menu #2
[
AR BEP
]
Function
: Selects the ARTS beep mode.
Available Values
: INRANG/ALWAYS/OFF
Default
: INRANG
INRANG: Activates the ARTS feature; a high tone beep will sound when the transceiver
first detects that you are within range, and a low beep will sound when the other
station goes out of range.
ALWAYS: Activates the ARTS feature; a high tone beep will sound every time a polling
transmission is received from the other station, and a low beep will sound once
when the other station goes out of range.
Menu #3
[
AR INT
]
Function
: Selects the Polling Interval during ARTS operation.
Available Values
: 25sec/15sec
Default
: 25sec
Menu #4
[
ARS
]
Function
: Activates/deactivates the Automatic Repeater Shift feature.
Available Values
: ARS.ON/ARS.OFF
Default
: Depends on the band of operation.
Menu #5
[
BEEP
]
Function
: Enables/disables the beeper
Available Values
: KEY/KEY+SC/OFF
Default
: KEY+SC
KEY:
The Beeper sounds when you press any key.
KEY+SC: The Beeper sounds when you press a key, or when the scanner stops.
OFF:
Disable the beeper.
Menu #6
[
CLK.SFT
]
Function
: Shifting of CPU clock frequency.
Available Values
: SFT.ON/SFT.OFF
Default
: SFT.OFF
This function is only used to move a spurious response “birdie,” should it fall on a desired
frequency.
M
ENU
(
“S
ET
”
)
M
ODE