d) Adjust VR1006 for 36 watts output.
e) Press the LOW switch and adjust
VR1005 for 5W output.
3) Frequency Calibration
a) Adjust TC1002 to match the coun-
ter indication with the transceiver
frequency.
4) Deviation
a) Set the AF generator for 25mV
output at 1 kHz. Adjust VR1003
f o r ± 4 . 5 kHz deviation on the
Deviation Meter.
b) Reduce the AF generator level to
5mV and adjust VR1004 for ±3.5
kHz deviation.
RECEIVER ALIGNMENT POINTS
26
ISa——L,-,-.,
< - V , o o ,
^^^-|r—Tp,o. (-), Tp4o, (+)
VRi 001
— — V R , 0 0 2
—
•
T
I
O
O
I