C. Receiver
Set up the test e q u i p m e n t as shown in
Figure 2. All adjustment points are on the
Main Unit.
d) Confirm 12dB SINAD sensitivity of
-7.5dBu (0.2 l u V ) or better on the
SINADDER.
Figure 2
RECEIVER ALIGNMENT SETUP
1) Interstage Transformers
a) Modulate the RF signal generator
for ±3.5 kHz deviation of a 1 kHz
tone.
b) Tune the transceiver and signal
generator to the same frequency
at the center of the band, and set
the i n j e c t i o n level to produce
midrange S-meter indication.
c) Adjust TC1001, L1004, T1001 and
C V I 001, in that order, for maximum
S-meter i n d i c a t i o n . Reduce the
injection level, if necessary, to
keep the S-meter near midrange.
2) S-Meter Calibration
a) At the center of the band, set the
signal generator for 30dBu (50uV)
injection with ±3.5 kHz deviation
of a 1 kHz tone.
b) Adjust VR1002 so that all S-meter
segments are just on.
3) Scanner Center-Stop
a) C o n n e c t the DC voltmeter ( 3 V
r a n g e ) b e t w e e n TP401 ( + ) and
TP402 (-) on the IF Unit.
b) Tune the transceiver to 435.000 or
445.000 M H z , and set the SQL
f u l l y counterclockwise (the BUSY
lamp should be lit).
c) Tune the signal generator to the
same frequency, and inject 20dBu
(5uV) with ±3.5 kHz deviation of a
1 kHz tone.
d) A d j u s t V R 1 0 0 1 for 0V on the
voltmeter.
27
Summary of Contents for FT-712RH
Page 4: ...PA UNIT APC UNIT 430 VCO UNIT LCD UNIT CONTROL UNIT BOARD LAYOUT 2...
Page 8: ...reverse view of chip only side 6...
Page 9: ...MAIN UNIT VOLTAGE CHART DC VOLTS MAIN UNIT 1C VOLTAGE CHART DC VOLTS...
Page 15: ...20 32 HD404418A01F 02003 obverse view of 1C side 14...
Page 16: ...S obverse view of 1C side 15 ANODE 1 CATHOOE 1...
Page 17: ......
Page 18: ...PA UNIT No 7 XX obverse view of component side reverse view of component side 17...
Page 19: ...obverse view of chip only side reverse view of chip only side 18...
Page 20: ...19...
Page 21: ...MAIN UNIT 20...
Page 22: ...21 e s A...
Page 23: ...22...