background image

11

12

Before Use

Before Use

About the Treatment Modes

 

Be sure to move the unit on your skin while using it.

(except when using the device on Eye Care/Cool Mode) 

 

Use of cottons on modes other than Clean/ Cool Mode is optional.

* The device may get hot after using the Cool Mode.

Do not use Cool Mode successively.

Allow the device to rest (with power off) at least half an hour after use.

* 1 To stratum corneum

* 2 If using your regular skin lotion, be sure that the skin lotion is water soluble.

Do not use oil-based or scrub-type skin lotions, as this could cause the device to 

malfunction or skin problems.

Mode

Product

Description

Function

Recommendations Time Level Frequency

(rough guide)

RF

Ion Cleansing

Vibration

RF

Ion Moisture

Vibration

RF

LED

RF

EMS

Cooling

Approx. 

3 minutes

Approx. 

3 minutes

Approx. 

3 minutes

Approx. 

3 minutes

Approx. 

3 minutes

Ion: 

5 levels

Ion: 

5 levels

EMS: 

5 levels

2 to 3 

times 

a week 

Everyday 

use is 

possible

Place on the skin directly.

Absorbs dirt which 

cannot be removed 

with normal face 

washing and tone 

your skin, while 

deeply warming the 

skin

1

.

Helps beauty 

ingredients to 

penetrate into the 

stratum corneum 

and moisturize your 

skin, while deeply 

warming the skin

1

.

Stimulates the 

muscles to make 

your skin elastic while 

deeply warming the 

skin

1

.

*Can also be used on 

the neck and 

shoulders.
Treats the skin 

with light while 

deeply warming 

the skin.

1

Improves skin 

elasticity and skin 

texture with cooling 

treatment.

How to Charge

1

Insert the AC adapter plug into the adapter socket of 

the main unit.

3

When charging is complete, unplug the AC adapter 

from the wall socket and then remove the adapter 

plug from the main unit.

2

Plug the AC adapter into the wall socket.

 

Use only with the supplied AC adapter.

 

Directly plug the AC adapter into a wall outlet and do not overload an 
electric circuit .

 

When charging had started, the Charge indicator will flash. When 
charging is complete, the Charge indicator will turn solid.

The product is rechargeable and can be used either with or without connecting to an 

AC adapter.

Always use the device after charging when you use device without an electrical cord.

 

Before using for the first time, or if you have not used the device for an extended 

period, fully charge the battery and make sure that the Charging indicator has 

turned from flashing to solid, indicating a full charge.

Charging the Battery

Charging time

Charge time

Operating time

Approx. 2.5 hours Approx. 40 minutes

* The time indicated at left is when the device is 

charged at an ambient temperature of around 25

˚

C.

* Charging time and operating time may vary 

depending on the operating Mode, operating 

level, and/or operating environment.

* Actual charging time will differ depending upon 

the remaining battery and the charging 

environment.

* Operating time is how long it can be used 

immediately after a full charge.

EYE CARE

A gentle electrical 

Micro-current treats 

the area around the 

eyes to improve 

elasticity.

RF

Micro-current

Approx. 

2 minutes N/A

N/A

N/A

RF Booster Pad Clear 

Deep Moisturizer

(If moisture is insufficient, 

add skin lotion remaining in 

the pouch.)

RF Booster Pad Pore 

Refining Deep Cleansing

(or your regular 

skin lotion

2

5 times 

a week 

2 to 3 

times 

a week 

Summary of Contents for Photo PLUS EX eye pro

Page 1: ...21 Product specifications 22 User s Manual Home care Beauty Device Photo PLUS EX eye pro Thank you for purchasing YA MAN product Please read this User s Manual carefully for safe and proper use After...

Page 2: ...ho have a disease of the eye s or face those who are currently undergoing treatment for a disease of the eye s or face Those with excessive myopia 6D or higher Do not use the device on various sites a...

Page 3: ...ng the device Do not disassemble attempt to repair or modify this device in any way Disassembly prohibited Failure to comply may cause an electric shock short circuit or fire Besuretoturnoffthepowerwh...

Page 4: ...the same body part Use the device appropriately based on your skin conditions After sunbathing do not use the device in combination with peeling skin packs or other treatments Always turn off the powe...

Page 5: ...main unit and accessories are subject to change for improvements without prior notes Cotton stopper is attached to electrode head when purchased Use this stopper to apply cotton to the head Adapter pl...

Page 6: ...Mode button the treatment mode will be selected in the following order Clean Moisture Eye Care EMS Up RF LED Cool Clean repeat Mode indicator RF Vibration Ion Cleansing RF Vibration Ion Moisture RF E...

Page 7: ...socket of the main unit 3 When charging is complete unplug the AC adapter from the wall socket and then remove the adapter plug from the main unit 2 Plug the AC adapter into the wall socket Use only w...

Page 8: ...for approx 3 seconds to turn on the power Select mode and intensity level Select the mode using the Power Mode button Select the intensity level using the Level Vibration button Press and hold the Lev...

Page 9: ...It is recommended to apply the device on one side of your face for 2 minutes a total of 4 minutes on both sides for those who are concerned about the dry skin around the eyes...

Page 10: ...the main unit 2 To clean the electrode head wipe it with a damped and well wrung cloth to remove dirt Wash the cotton stopper with water Remove the cotton stopper from the main unit and wash it with...

Page 11: ...feel anything Cool Mode is not very cool Device is being used in a temperature environment exceeding the recommended range Try using in the environment with the temperature of 15 C to 30 C Cool Mode w...

Page 12: ...ion battery Contact Contact your local distributor for any question you may have regarding the warranty that applies to the device repairs of the device or other matters requiring clarification Voltag...

Reviews: