background image

13

14

How to Use

How to Use

How to Use

Attaching Cotton to the Head

1

Remove the cotton stopper 

from the electrode head.

2

Place the cotton on top of the electrode 

head and press the cotton stopper down over the cotton.

* If the cotton stopper does not fit properly on the electrode head, use a thinner 

cotton.

* If the cotton is too thick, the thermal action of RF treatment may be adversely 

affected and you will feel less heat.

3

Apply your regular skin lotion or gel onto the cotton.

* Make sure that the lotion or gel coats the entire surface of the treatment head.

* If using a smooth (low-viscosity) skin lotion, the feeling of warmth may 

decrease.

Recommended skin lotions: RF Booster Pad/high-viscosity skin lotions

* This device is not water-proof so be sure to thoroughly wipe off any lotion or 

gel left on the device with a dry cloth after each use.

Do not wash with water or other liquids.

● For how to use RF Booster Pads, please refer to the instructions 

provided separately.

7

After treatment, condition your skin as necessary.

• Please apply skin cream as appropriate.

6

Press the Power/Mode button for approx. 3 seconds 

to turn off the power.

• When treatment on Cool Mode has finished, the power will turn off 

automatically.

8

Remove cotton from the electrode head and wipe off any 

residue of skincare lotion or gel remaining on the electrode 

head or cotton stopper.

* This product is not water-proof so be sure to thoroughly wipe off any lotion or 

gel left on the device with a dry cloth after each use.

Do not wash with water or other liquids. 

1

Remove makeup and gently cleanse your face.

• Remove oil and dirt from your skin so that it is in a clean condition prior to 

treatment.

* Cool Mode can be used over makeup.

3

Press the Power/Mode button for approx. 3 seconds to turn 

on the power. Select mode and intensity level.

• Select the mode using the Power/Mode button.

• Select the intensity level using the Level/Vibration button.

• Press and hold the Level/Vibration button for about three seconds to switch the 

vibration function ON/OFF.

(When using Clean/Moisture Mode,)

* The device does not vibrate on EYE CARE, EMS UP, RF LED or Cool Mode.

* Intensity level cannot be selected for Eye Care/RF LED/ Cool Mode

* RF intensity level cannot be selected.

* Always select Level 1 upon the first use until you are accustomed to use.

2

Attach cotton if necessary and apply lotion onto the cotton.

●Treatment method

4

Hold the device so that you are touching the hand 

electrode (silver rim) on the rear of the device.

5

Gently apply the treatment head to your skin and move the head 

over the area being treated. (Refer to p.15-16 for more details)

• When the Mode is finished, the device will go into standby for 2 min. After using 

the Cool Mode, the device will automatically turn off.

Either press the Power/Mode button to start the next mode, or press the 

Power/Mode button for approx. 3 seconds to turn off the power.

* During use, make sure that the electrode head is firmly touching the skin.

How to Use (General Instructions)

●Precautions when using

● Be sure to move the unit on your skin while using it. Using the device 

continuously on the same area may cause burns or other injuries.

● The temperature of RF may feel different depending upon the condition of 

your skin and types of cosmetics used together.

● Do not use on eyelids or around the eyes (except when using the device 

on Eye Care or Cool Mode)

* RF LED Mode can be used on eyelids and around the eyes. Close your eyes 

and hold the device 5cm away from your eyes.

● Do not look directly into the LED light when using the device on RF LED 

Mode.

● Be sure to hold the device so that your hand is touching the electrode 

head.

● Recommended ambient temperature is 15°C ~ 30°C.

Summary of Contents for Photo PLUS EX eye pro

Page 1: ...21 Product specifications 22 User s Manual Home care Beauty Device Photo PLUS EX eye pro Thank you for purchasing YA MAN product Please read this User s Manual carefully for safe and proper use After...

Page 2: ...ho have a disease of the eye s or face those who are currently undergoing treatment for a disease of the eye s or face Those with excessive myopia 6D or higher Do not use the device on various sites a...

Page 3: ...ng the device Do not disassemble attempt to repair or modify this device in any way Disassembly prohibited Failure to comply may cause an electric shock short circuit or fire Besuretoturnoffthepowerwh...

Page 4: ...the same body part Use the device appropriately based on your skin conditions After sunbathing do not use the device in combination with peeling skin packs or other treatments Always turn off the powe...

Page 5: ...main unit and accessories are subject to change for improvements without prior notes Cotton stopper is attached to electrode head when purchased Use this stopper to apply cotton to the head Adapter pl...

Page 6: ...Mode button the treatment mode will be selected in the following order Clean Moisture Eye Care EMS Up RF LED Cool Clean repeat Mode indicator RF Vibration Ion Cleansing RF Vibration Ion Moisture RF E...

Page 7: ...socket of the main unit 3 When charging is complete unplug the AC adapter from the wall socket and then remove the adapter plug from the main unit 2 Plug the AC adapter into the wall socket Use only w...

Page 8: ...for approx 3 seconds to turn on the power Select mode and intensity level Select the mode using the Power Mode button Select the intensity level using the Level Vibration button Press and hold the Lev...

Page 9: ...It is recommended to apply the device on one side of your face for 2 minutes a total of 4 minutes on both sides for those who are concerned about the dry skin around the eyes...

Page 10: ...the main unit 2 To clean the electrode head wipe it with a damped and well wrung cloth to remove dirt Wash the cotton stopper with water Remove the cotton stopper from the main unit and wash it with...

Page 11: ...feel anything Cool Mode is not very cool Device is being used in a temperature environment exceeding the recommended range Try using in the environment with the temperature of 15 C to 30 C Cool Mode w...

Page 12: ...ion battery Contact Contact your local distributor for any question you may have regarding the warranty that applies to the device repairs of the device or other matters requiring clarification Voltag...

Reviews: