Treatment

Treatment

Treatment preparations

In order to ensure that the device works as intended, make sure to undertake preparations prior to carrying 
out a treatment.

* Make sure to perform this test before using the device for the first time.

Test the Flash on a patch of skin

1

Apply flash to an inconspicuous site near the intended treatment 
site starting from level 1 in single mode.

For more information on how to apply a treatment, see “How to use each mode” (pages 17 through 
22).
* Do not perform multiple tests on the same site. Always perform multiple tests by shifting the site 

each time.

2

After performing the test, wait twenty-four hours before checking 
your skin.

You can use the device if no abnormalities can be seen on your skin (such as redness, a blister, or 
inflammation).

1

Make sure to get rid of excess hair at the site to be treated.

* A burn injury may result if excess hair is allowed to grow long or remain on the surface of the skin.

* Avoid tweezing or removing hair with wax or other such means.

Use a handheld shaver.

2

Verify that neither the lamp head nor treatment window is in an 
abnormal state.

 Make sure to clean the device if it is dirty.

Failure to comply may cause a failure or degradation of the device, a burn injury or other type of 
injury, or skin problems.
See “How to clean” (page 23) for more information on how to clean the device.

Refrain from using the device when it is damaged or deformed.

16

15

Flash level setting

Use the device after setting the flash to a level at which warmth or a little heat can be felt.

Attention

DO NOT use the device if it is set to a level at which pain can be felt.

Use the device while adjusting the level.

Adjust the level since your perception will differ depending on the site where the 
device is used.

DO NOT use the device if it is set to an unreasonably high level.

In particular, the skin of a darker-skinned person or a person who has gotten 
suntanned will more easily absorb light. For such persons, failure to comply may 
cause skin problems.

Treatment steps

Make sure to carry out a flash treatment after removing excess hair.

Shaving (using a tool other than the device; performed by the user)

→②

Flash treatment (using the device)

* If you are concerned about hot flashes of the skin, sufficiently cool down the skin by applying a cold pack 

or cold towel to the site in question.

Before using

Treatment frequency

* In single mode, do not treat the same site twice or more times per day.
* Results will differ depending on the site where the device is used and the individual user.
* In roller mode, each body part should be treated no more than five minutes per day.
* If you do not perceive any results from using the device, continue to maintain the initial treatment 

frequency.

* This device is not intended to be used to permanently remove hair.

Suspending the treatment may cause you to feel that the volume of unwanted hair is gradually being 
restored to what it was prior to using the device.

First 2 months

Once every 2 weeks

Third and subsequent months

Once per 4 to 8 weeks

Attention

DO NOT engage in excessive use of the device.

If you wish to use the device in excess of the aforementioned frequency, make sure 
to use the device while checking the condition of the skin. In addition, always 
adhere to the prescribed maximum number of times the device can be used per 
day.
Failure to comply may cause skin problems.

Summary of Contents for Beaute R Flash

Page 1: ...ts hereof make sure to store this User s Manual in an accessible location Make sure to include this User s Manual if you are transferring ownership of the device to another person Table of contents Safety precautions 1 When using outside Japan 8 Names of parts 9 Before using 11 Treatment 16 How to use each mode 17 After treatment 23 Troubleshooting 25 After sales service 29 Product specifications ...

Page 2: ...in question prior to using the device The following persons should not utilize the device Prohibited Safety precautions Warning 2 1 Safety precautions Safety precautions Carefully read these Safety precautions before properly utilizing the device Sensibly utilize the device in accordance with the prescribed steps If an abnormality arises immediately discontinue the use of the device and arrange to...

Page 3: ...circuit Overloading an electric circuit prohibited Failure to comply may cause an injury Use by unattended children or persons with physical disabili ties should be avoided A minor should use the device with the consent and under the supervi sion of his or her guardian User restrictions Failure to comply may cause an injury or a failure of the device DO NOT use the device for any purpose other tha...

Page 4: ...ice can be used should range between 10 and 40 degrees centigrade Verify the ambient temperature of the location where the device will be used The device may not correspond e f f e c t i v e l y t o t h e a m b i e n t temperature of a new location immediately after moving to the new location Failure to comply may cause the device to fail or break Ensure that the temperature of the usage environme...

Page 5: ... Switzerland China Hong Kong India Singapore Philippines Egypt South Africa Canada U K Switzerland Thailand South Korea Singapore China Hong Kong Egypt South Africa Italy Holland Switzerland Spain Germany France India Thailand South Korea China Hong Kong Malaysia Turke U K France Australia New Zealand South Korea Taiwan China Philippines Argentina Major types of plug shapes and the countries in wh...

Page 6: ...nd peripheral accessories are subject to change for improvement purposes without notice Names of parts Main body Vent holes Lamp head Filter yellow tinted transparent glass Glass tube Power level button Indicator panel Roller small Roller large Treatment window Vent holes Grip Flash button In single mode READY lamp In single mode Adapter plug insertion port ...

Page 7: ...e single BODY mode The device can render unwanted hair inconspicuous and allow you to carry out a facial treatment by administering instantaneous flashes of light to the skin using a xenon lamp Use the device by selecting the mode according to the site where the device will be used Roller mode Use by extending the grip in a straight line Glide the device with the treatment window in contact with t...

Page 8: ...ighting that is excessively dark Under a table or otherwise in the shadows Power level button On Connect the AC adapter and hold down the button approx 3 seconds to turn on the device Roller mode Standby state meter indicator will blink in a blue color Single mode The level indicator meter indicator and BODY mode FACE mode indicator will be lit For more details on modes see Modes page 11 Off After...

Page 9: ...t to a level at which pain can be felt Use the device while adjusting the level Adjust the level since your perception will differ depending on the site where the device is used DO NOT use the device if it is set to an unreasonably high level In particular the skin of a darker skinned person or a person who has gotten suntanned will more easily absorb light For such persons failure to comply may c...

Page 10: ...r Injury scar or other dark colored site Eyeball Eyelid around the eye Acne Pigmentation or mole Eyebrow forehead or scalp hair Suntanned site Anywhere inside the mouth on the lip around the pubic region or any mucous membrane Adam s apple Ear Nipple areola Inside the belly button Site where a large artery or other blood vessel can be seen Tattoo or body painted site Site to which makeup has been ...

Page 11: ...om the device and clean the device and lamp head Clean after each use according to How to clean page 23 Refrain from taking a bath shower is permitted exercising or drinking alcoholic beverages on the day of a treatment 20 19 How to use the single mode 1 Insert the adapter plug into the port on the device for the adapter plug and insert the AC adapter into a wall outlet 4 Press the power level but...

Page 12: ...ation or mole Eyebrow forehead or scalp hair Suntanned site Anywhere inside the mouth on the lip around the pubic region or any mucous membrane Adam s apple Ear Nipple areola Inside the belly button Site where a large artery or other blood vessel can be seen Tattoo or body painted site Site to which makeup has been applied When carrying out a treatment keep the following tips in mind Treatment of ...

Page 13: ...e of the device or skin problems After Treatment Warning Unplug the AC adapter from the wall outlet before cleaning the device Failure to comply may cause an electric shock short circuit or fire Clean in a manner that prevents water from infiltrating the device Failure to comply may cause an electric shock short circuit or fire After Treatment How to store When the device will not be in use for an...

Page 14: ...er ated Refer to Error indications page 27 An error condition is in effect Make sure that the AC adapter is properly inserted The AC adapter connection is loose The device shuts off To resume using the device wait at least ten minutes before proceeding The auto off feature is activated ten minutes after the flash button is pressed Troubleshooting Troubleshooting Condition Possible causes Solution ...

Page 15: ...o the treatment of suntanned skin with flash pulses Remove excess hair and use the device on skin that has not been suntanned If redness or pain is manifested discontinue use immediately and cool down and moisturize the skin If there is no amelioration discontinue using the device and see a physician How many times a day can I use the device In single mode the application of flash pulses on the sa...

Page 16: ...0 g including the lamp head Japan Main body ABS resin polycarbonate Lamp head ABS resin nylon aluminum stainless steel glass Device 1 unit AC adapter 1 unit Product specifications Disposing of the device If you wish to dispose of the device proceed in accordance with applicable local government rules governing the sorting of waste products After sales service After sales service 29 30 After sales ...