background image

12

11

Before using

Before using

Before using

With this mode, glide the treatment window over the skin to 
emit flashes automatically and continuously.
Recommended for treating legs, arms, and other expansive 
sites.

* Do not use the device in this mode on the face.

Roller mode

This mode allows you to carry out treatments on your body.
Recommended for treating the underarm area, fingertips, and 
other narrowly-focused sites.

Body mode
(indicated in green 
characters)

This mode allows you to carry out treatments on your face.

Face mode
(indicated in white 
characters)

With this mode, carefully carry out treatments one session at 
a time.
Recommended when using the device for the first time or for 
treating narrowly-focused sites.

Single mode

Modes

Mode

Characteristics

For more

information

P.18

P.20

About the roller mode and single mode

By extending the grip of the device in a straight line or bending the grip, you can use the device to 
administer continuous-pulse flashes (roller mode) or single-pulse flashes (single FACE mode/single BODY 
mode).

The device can render unwanted hair inconspicuous and allow you to carry out a facial treatment by 
administering instantaneous flashes of light to the skin using a xenon lamp.
Use the device by selecting the mode according to the site where the device will be used.

Roller mode: Use by extending the grip in a straight line.

Glide the device with the treatment window in contact with the skin to rotate the roller, which 
in turn causes flash pulses to be discharged continuously.
The meter indicator lets you know how many more flash pulses can be emitted.
* Each time the level is raised, the interval between each flash pulse will gradually lengthen.

Single mode: Use by bending the grip.

Each time you press the flash button that appears when you bend the grip, a flash pulse will 
be discharged.
Since you can choose between FACE mode and BODY mode in the single mode, select the 
mode according to the site where you wish to use the device.
* Do not treat the same site continuously at a high level. Make sure to use the device while 

moving the treatment window from one site to the next.

Attention

When treating your face, make sure you use FACE mode.

Using BODY mode may cause a burn injury or other problems.

Summary of Contents for Beaute R Flash

Page 1: ...ts hereof make sure to store this User s Manual in an accessible location Make sure to include this User s Manual if you are transferring ownership of the device to another person Table of contents Safety precautions 1 When using outside Japan 8 Names of parts 9 Before using 11 Treatment 16 How to use each mode 17 After treatment 23 Troubleshooting 25 After sales service 29 Product specifications ...

Page 2: ...in question prior to using the device The following persons should not utilize the device Prohibited Safety precautions Warning 2 1 Safety precautions Safety precautions Carefully read these Safety precautions before properly utilizing the device Sensibly utilize the device in accordance with the prescribed steps If an abnormality arises immediately discontinue the use of the device and arrange to...

Page 3: ...circuit Overloading an electric circuit prohibited Failure to comply may cause an injury Use by unattended children or persons with physical disabili ties should be avoided A minor should use the device with the consent and under the supervi sion of his or her guardian User restrictions Failure to comply may cause an injury or a failure of the device DO NOT use the device for any purpose other tha...

Page 4: ...ice can be used should range between 10 and 40 degrees centigrade Verify the ambient temperature of the location where the device will be used The device may not correspond e f f e c t i v e l y t o t h e a m b i e n t temperature of a new location immediately after moving to the new location Failure to comply may cause the device to fail or break Ensure that the temperature of the usage environme...

Page 5: ... Switzerland China Hong Kong India Singapore Philippines Egypt South Africa Canada U K Switzerland Thailand South Korea Singapore China Hong Kong Egypt South Africa Italy Holland Switzerland Spain Germany France India Thailand South Korea China Hong Kong Malaysia Turke U K France Australia New Zealand South Korea Taiwan China Philippines Argentina Major types of plug shapes and the countries in wh...

Page 6: ...nd peripheral accessories are subject to change for improvement purposes without notice Names of parts Main body Vent holes Lamp head Filter yellow tinted transparent glass Glass tube Power level button Indicator panel Roller small Roller large Treatment window Vent holes Grip Flash button In single mode READY lamp In single mode Adapter plug insertion port ...

Page 7: ...e single BODY mode The device can render unwanted hair inconspicuous and allow you to carry out a facial treatment by administering instantaneous flashes of light to the skin using a xenon lamp Use the device by selecting the mode according to the site where the device will be used Roller mode Use by extending the grip in a straight line Glide the device with the treatment window in contact with t...

Page 8: ...ighting that is excessively dark Under a table or otherwise in the shadows Power level button On Connect the AC adapter and hold down the button approx 3 seconds to turn on the device Roller mode Standby state meter indicator will blink in a blue color Single mode The level indicator meter indicator and BODY mode FACE mode indicator will be lit For more details on modes see Modes page 11 Off After...

Page 9: ...t to a level at which pain can be felt Use the device while adjusting the level Adjust the level since your perception will differ depending on the site where the device is used DO NOT use the device if it is set to an unreasonably high level In particular the skin of a darker skinned person or a person who has gotten suntanned will more easily absorb light For such persons failure to comply may c...

Page 10: ...r Injury scar or other dark colored site Eyeball Eyelid around the eye Acne Pigmentation or mole Eyebrow forehead or scalp hair Suntanned site Anywhere inside the mouth on the lip around the pubic region or any mucous membrane Adam s apple Ear Nipple areola Inside the belly button Site where a large artery or other blood vessel can be seen Tattoo or body painted site Site to which makeup has been ...

Page 11: ...om the device and clean the device and lamp head Clean after each use according to How to clean page 23 Refrain from taking a bath shower is permitted exercising or drinking alcoholic beverages on the day of a treatment 20 19 How to use the single mode 1 Insert the adapter plug into the port on the device for the adapter plug and insert the AC adapter into a wall outlet 4 Press the power level but...

Page 12: ...ation or mole Eyebrow forehead or scalp hair Suntanned site Anywhere inside the mouth on the lip around the pubic region or any mucous membrane Adam s apple Ear Nipple areola Inside the belly button Site where a large artery or other blood vessel can be seen Tattoo or body painted site Site to which makeup has been applied When carrying out a treatment keep the following tips in mind Treatment of ...

Page 13: ...e of the device or skin problems After Treatment Warning Unplug the AC adapter from the wall outlet before cleaning the device Failure to comply may cause an electric shock short circuit or fire Clean in a manner that prevents water from infiltrating the device Failure to comply may cause an electric shock short circuit or fire After Treatment How to store When the device will not be in use for an...

Page 14: ...er ated Refer to Error indications page 27 An error condition is in effect Make sure that the AC adapter is properly inserted The AC adapter connection is loose The device shuts off To resume using the device wait at least ten minutes before proceeding The auto off feature is activated ten minutes after the flash button is pressed Troubleshooting Troubleshooting Condition Possible causes Solution ...

Page 15: ...o the treatment of suntanned skin with flash pulses Remove excess hair and use the device on skin that has not been suntanned If redness or pain is manifested discontinue use immediately and cool down and moisturize the skin If there is no amelioration discontinue using the device and see a physician How many times a day can I use the device In single mode the application of flash pulses on the sa...

Page 16: ...0 g including the lamp head Japan Main body ABS resin polycarbonate Lamp head ABS resin nylon aluminum stainless steel glass Device 1 unit AC adapter 1 unit Product specifications Disposing of the device If you wish to dispose of the device proceed in accordance with applicable local government rules governing the sorting of waste products After sales service After sales service 29 30 After sales ...

Reviews:

Related manuals for Beaute R Flash