3
working surface of the tip as possible. This results in both a rapid heat up, fast recovery and
exacting temperature control with minimal overshoot.
The revolutionary “Zero Voltage” electronic switching design also protects voltage and
current sensitive components (CMOS devices etc.) against damaging current and transient
voltage spikes commonly produced by less efficient, mechanically switched stations. The
power unit is isolated from the A.C. line by a transformer and allows 32Vac for soldering
and desoldering to drive the heating elements.
The new LF-8800 has been developed to meet the present and future needs of the electronic
production industry and is ideal for use at any AC outlet. Engineered to meet the
demanding needs of the hobbyist, service & repair technician as well as production people
alike.
BRIEF INTRODUCTION OF PANEL FUNCTIONS:
Front panel
○
○
○
○
1111
Main power switch
○
○
○
○
2222
SIA
:
Solder/Tweezer wand
socket
○
○
○
○
3 HAP: Hot air fitting
○
○
○
○
4 DIA: Desolder/HAP wand
socket
○
○
○
○
5
VAC: Desoldering vacuum
tube fitting
○
○
○
○
6
“▲” – “Up” key
○
○
○
○
7 “▼” – “Down” key
⑧
⑧
⑧
⑧
“SET” - Function key
○
○
○
○
9 Temperature display readout
○
○
○
○
10 Degrees Celsius or Fahrenheit display
○
○
○
○
11 Heat indicating light