background image

 

the unit will be under the status of no password. If the user sets “100” then means the 
unit will be under the password status. Press “SET” key once to finish password 
setting and the unit will backup mode, the user can continue set other modes or back 
from the setting mode.   

 

4.

 

Temperature Correction Setting   

Press “SET” key once when the LED displays “F-2” and flashes that the unit enters 
the Temperature Correction Mode. At this moment, the LED displays preset correction 
value.   

         

A: Operation of    Centigrade temperature correction

(Range +99℃~-99℃)

 

Press “▲” or “▼” key to change the temperature correction value.The first digit “— ” 
in LED display means minus (actual temperature is down), “No display” means plus 
(actual temperature is up). 

 

B: Operation of    Fahrenheit temperature correction

(Range +178℉~-178℉)

 

Press “▲” or “▼”key to change the temperature correction value. The first digit “— ” 
in LED display means minus (actual temperature is down), “No display” means plus 
(actual temperature is up). 

 

Press “SET” key once to finish the temperature correction and the unit automatically 
backup mode. The user may continue set other modes or back from the current setting 
mode.     

Example for temperature correction: 

A:The temperature set to the 

℃:

 The current set temperature value is 300

℃,

 however, 

the actual temperature is only 290

. So it needs to correct by +10

. Correction method: 

if the current correction value is 00 or -00; then change it to 10. If the current correction 
value is -20, then change it to -10. If the current correction value is 20, then change it to 
30. 

  B: The temperature set to the 

℉:

 The current set temperature value is 392

℉,

 however, 

the actual temperature is only 374

. So it needs to correct by +18

. Correction method: 

if the current correction value is 00; then change it to 18. If the current correction value is 
-20, then change it to -02. If the current correction value is 20, then change it to 38. 

 

5.

 

Sleep Mode Set   

Press “SET” key one time when the LED displays “F-3” and flashes, the unit enters the 

Sleep mode status. At this moment, the LED displays the pre-set value. Press “▲” or 
“▼” key to change the set value. If set value reads “000” that means the unit set in 
“Sleep” mode releasing status. If the display read “100” that means the unit set in 
“Sleep” mode. Press “SET” key once to finish the sleep mode setting, then the unit 
automatically backup. The user may continue set other modes or back from current set 
mode.   

*Please note the manufacturer original design will keep in “Free” status without setting 

“Sleep” mode. 

 

Dystrybucja i serwis

Dane kontaktowe:

NDN - Zbigniew Daniluk
ul. Janowskiego 15
02-784 Warszawa

tel.: (22) 641-15-47
e-mail: [email protected]
NIP: 521-044-00-73

Summary of Contents for LF- 8800

Page 1: ...oldering Desoldering Station For Lead free soldering application and rework on professional SMD electronics Dystrybucja i serwis Dane kontaktowe NDN Zbigniew Daniluk ul Janowskiego 15 02 784 Warszawa...

Page 2: ...erial when in operation The soldering and desoldering tip and the heating element are still remaining hot after being switched off Ensure that you do not touch the tips and the heating elements For yo...

Page 3: ...ering iron as an option Be sure before proceeding this operation the main switch must be OFF to avoid any damage to the unit PRODUCT DESCRIPTION LF 8800 operates with the high power 32V 100W output th...

Page 4: ...w LF 8800 has been developed to meet the present and future needs of the electronic production industry and is ideal for use at any AC outlet Engineered to meet the demanding needs of the hobbyist ser...

Page 5: ...st 5 seconds until display shows sign then release the SET key The sign starts to flash and reminding the user to input the mode lock password 010 fixed If the user inputs the same number as 010 the u...

Page 6: ...t set temperature value is 300 however the actual temperature is only 290 So it needs to correct by 10 Correction method if the current correction value is 00 or 00 then change it to 10 If the current...

Page 7: ...d blinking press the SET button at this time the system enters the degrees Fahrenheit and Centigrade temperature selection function indicating the temperature of the window shows the current status Pr...

Page 8: ...trip c One 0 7 probe d 4pcs of filters 4 Optional parts A TWZ90 32V 100W Tweezers can be interchangeable with soldering iron B HAP80 32V 80W Hot air blow pencil can be interchangeable with DIA100 OPER...

Page 9: ...the tip has been removed otherwise the tip may clog 3 Add solder to the joint of the component and allow the solder to melt completely for improved desoldering 4 Remove the solder collector and clean...

Page 10: ...ip when soldering The flux is naturally caustic and thus will eat away the tip 5 Never clean the tip with a file or abrasive materials 6 Do not use fluxes which contain chloride or acid Use only rosin...

Page 11: ...l nut assembly The station must be turned off and allowed to cool before this operation If the system is left on without a tip in place damage to the iron assembly may occur After removing the tip blo...

Page 12: ...be unclogged Replace the tip and screw back the retaining barrel nut assembly but care should be taken not to over tighten PROCEDURES FOR CLEANING THE SOLDER COLLECTOR CAUTION The desolder switch mus...

Page 13: ...long nose pliers or tweezers see Figures 13 14 FIG 13 FIG 14 5 Clean the cooling strip and glass collector with wire brush included PROCEDURE FOR REPLACING FILTERS SOLDER COLLECTOR FILTERS 1 Be sure...

Page 14: ...LTERS 1 Unscrew in line filter see Figure 19 and then pull apart Figure 20 FIG 19 FIG 20 INTERCHANGEABLE TIPS FOR LF 8800 Desoldering tips for DIA100 Dystrybucja i serwis Dane kontaktowe NDN Zbigniew...

Page 15: ...p damaged easily Change of Glass Solder Collector 75 160110 Glass solder collector will be broken easily if the client knocked the DIA100 against the desktop The glass collector also needs to be chang...

Reviews: