Soldering tips for 307A
MAINTENANCE NOTE FOR DIA100
Change of Cotton Filament (76-1411030):
Please note that the cotton filament cannot be washed with the water. Water drops would be
sucked into the Pump and may cause the pump damaged within 1 to 2 months. If you wash
with the water,
Cotton filament
will turn solid and will stop the DIA100 working well.
Please change
at least
once 3 to 5 days if you use
8 hours
per day.
Change of Charcoal Filter (78-151500):
Charcoal filter will turn solid if you wash with the water. If you use 8 hours per day that the
Charcoal filter has to be changed within 3 weeks. On the other hand, if you wash the
Charcoal filter and do not dry properly, water drops will be sucked into the Pump and may
cause the pump damaged easily.
Change of Glass Solder Collector (75-160110):
Glass solder collector will be broken easily if the client knocked the DIA100 against the
desktop. The glass collector also needs to be changed every 3 to 5 months usage.
Maintenance for Desoldering Heater and Tip:
To prevent the desoldering tip being stuck by solder, the desoldering tip has to be cleaned
by a Probe after every time usage. In such ways, desoldering tip’s life can be lasting longer.
Desolder Heater would be probably broken when you remove the desoldering tip with a
pliers careless in hot condition. Slightly remove the tip with pliers or may use the anti-rusty
cleaner when the tip clogged with the heater and do not forced open. Please read the
“
Procedure for
Cleaning Clogged Tips
” carefully on page9 on the manual.