background image

15 

 

Change of Cotton Filament (76-1411030): 

Please note that the cotton filament cannot be washed with the water. Water drops 

would be sucked into the Pump and may cause the pump damaged within 1 to 2 

months. If you wash with the water, 

Cotton filament

 will turn solid and will 

stop the DIA60T working well. Please change 

at least 

once 3 to 5 days if you 

use

 8 hours 

per day.   

 

Change of Charcoal Filter (78-151500):

 

Charcoal filter will turn solid if you wash with the water. If you use 8 hours per day 

that the Charcoal filter has to be changed within 3 weeks. On the other hand, if 

you wash the Charcoal filter and do not dry properly, water drops will be sucked 

into the Pump and may cause the pump damaged easily. 

 

Change of Glass Solder Collector (75-160110): 

Glass solder collector will be broken easily if the client knocked the DIA60T against 

the desktop. The glass collector also needs to be changed every 3 to 5 months 

usage. 

 

Maintenance for Desoldering Heater and Tip: 

To prevent the desoldering tip being stuck by solder, the desoldering tip has to be 

cleaned by a Probe after every time usage. In such ways, desoldering tip’s life 

can be lasting longer. Desolder Heater would be probably broken when you 

remove the desoldering tip with a pliers careless in hot condition. Slightly 

remove the tip with pliers or may use the anti-rusty cleaner when the tip clogged 

with the heater and do not forced open. Please read the “

Procedure for

 

Cleaning Clogged Tips

” carefully on page.3 & 4 on the manual.     

 

Summary of Contents for LF-8000

Page 1: ...been serving the electronics industry for over 25 years and with its many special features have proven to be the ultimate in a soldering desoldering instrument Please carefully read the instruction ma...

Page 2: ...se LED is lit the energy saver feature has engaged decreasing tip temperature by 1 3 which cuts power consumption and extends tip life CELSIUS FAHRENHEIT SWITCH To address the global market place a co...

Page 3: ...also protects voltage and current sensitive components CMOS devices etc against damaging current and transient voltage spikes commonly produced by less efficient mechanically switched stations The pow...

Page 4: ...S OPERATING PROCEDUCRES FOR LF 8000 1 Ensure that the working voltage matches your power supply before beginning use 2 Check carefully for any damage during transportation 3 This unit contains A DIA80...

Page 5: ...soldering desoldering irons can be used at same time 2 If LF 8000 is idle for more than 15 minutes an energy saving feature will automatically engage evident by the green PUASE indicator light reduci...

Page 6: ...may clog 3 Add solder to the joint of the component and allow the solder to melt completely for improved desoldering 4 Remove the solder collector and clean it after no more than 200 applications Howe...

Page 7: ...r low tin content CARE OF TIPS CAUTION The soldering desoldering irons can reach very high temperature Be sure to turn the unit off prior to carrying out any maintenance or trouble shooting steps list...

Page 8: ...he tip may fuse to the heating element or retaining barrel METHOD TO CHECK FOR LOSS OF SUCTION The following procedures should be used on LF 8000 to check whether loss of suction is due to the tip sol...

Page 9: ...ring screw for the barrel nut assembly Pliers can be used to avoid contact with hot surfaces BUT SHOULD BE USED WITH CAUTION because over tightening may cause damage to the element or fuse the tip to...

Page 10: ...unclogged Replace the tip and screw back the retaining barrel nut assembly but care should be taken not to over tighten PROCEDURES FOR CLEANING THE SOLDER COLLECTOR CAUTION The desolder switch must be...

Page 11: ...ir of long nose pliers or tweezers see Figures 13 14 5 Clean the cooling strip and glass collector with wire brush included Page 9 PROCEDURE FOR REPLACING FILTERS SOLDER COLLECTOR FILTERS 1 Be sure th...

Page 12: ...5 Remove old cotton filter and replace see Figures 17 18 IN LINE FILTERS 1 Unscrew in line filter see Figure 19 and then pull apart Figure 20 INTERCHANGEABLE TIPS FOR LF 8000 11...

Page 13: ...mperature range F 300 800 F Standard tip 46 060102 SMD TIPS FOR TWZ100 TIP TYPES SUITABLE COMPONENTS Flat pack IC s Small outlet 8 24 pins Flat package tunnel types Dip IC s 46 060110 10mm 46 060115 1...

Page 14: ...13...

Page 15: ...Maintenance note for DIA80 Desoldering Iron Heater operation voltage V ac 32Vac Heater power consumption Watt 80W C 300 450 C Temperature range F 572 842 F Standard tip 44 915412 2075 DIA80 SPARE PART...

Page 16: ...l be sucked into the Pump and may cause the pump damaged easily Change of Glass Solder Collector 75 160110 Glass solder collector will be broken easily if the client knocked the DIA60T against the des...

Reviews: