SonTek, a Xylem brand
84
RiverSurveyor S5/M9 System Manual (February 2013)
Figure 105. Thresholds - Processing Toolbox
8.4.
Hot Keys/Accelerators
Table 3 presents a list of Hotkeys/Accelerators which can be used via the keyboard, often in
place of a mouse click. These Hot Keys are useful in many processes including data collection,
data processing, managing data files and viewing data. It is also important to remember for
graphic and tabular display, a right-click presents data viewing options.
Table 3. Summary of Hotkeys/Accelerators for RiverSurveyor Live for PC
Hot Keys
Description/Function
Location/Process
F5
Go to Next Step
Data Collection
F8
Abort
Data Collection
Ctrl+N
Connect to RiverSurveyor System
Start Data Collection
Ctrl+O
Open a data file
Data Processing
Ctrl+T
Show/Hide Processing Toolbox
Data Processing
Ctrl+S
Show/Hide Discharge Measurement Summary
Data Processing
Ctrl+R
Show Discharge Summary Report
Data Processing
Ctrl+Tab
Next File/Connection Tab (top of screen)
Data Processing
Ctrl+Shift+Tab
Previous File/Connection Tab (top of screen)
Data Processing
PageUp
Next Display Tab (bottom of screen)
Data Processing
PageDown
Previous Display Tab (bottom of screen)
Data Processing
Ctrl+F4
Close Current Tab
Data Processing
Ctrl++
Increase Vector Length
Track Window
Ctrl--
Decrease Vector Length
Track Window
Z
Zoom in
Track Window
Shift+Z
Zoom out
Track Window
Left Arrow
First Sample
Data Files
Right Arrow
Last Sample
Data Files
Up Arrow
Previous Sample
Data Files
Down Arrow
Next Sample
Data Files
Ctrl+Up Arrow
Back 20 Samples
Data Files
Ctrl+Down Arrow
Forward 20 Samples
Data Files
Ctrl+Shift+Up Arrow
Back 100 Samples
Data Files
Ctrl+Shift+Down Arrow
Forward 100 Samples
Data Files
8.5.
Processing Data Files – Step by Step
This section is a guide for analyzing and post-processing data files collected in the field.
1. Open all files from a measurement site (the same measurement site with the same
flow conditions).
o
Review the System settings. Be sure that the settings are consistent amongst
files. To do this go to the Systems tab and cycle through each file (Click on each
tab individually or use Ctrl+Tab).
o
If necessary, change the Track and Depth reference to best represent the best
field measurement (in Processing Toolbox – System Settings).
o
Select the Navigation tab to evaluate the collected data across the channel. De-
activate the UTM Display and activate the AutoScale option: available by right
clicking.
o
Use the Sidebar tabular data to evaluate specific settings (i.e. Duration of the
measurement, GPS Quality).