en - Original instructions
Genyo plus, Additional Installation, Operation and Maintenance Instructions
19
5
Use and operation
5.1
Precautions
WARNING:
Make sure that the drained liquid cannot cause damage or injuries.
WARNING: Electrical hazard
Check that the unit is properly connected to the mains power supply.
WARNING:
It is prohibited to put combustible materials near the unit.
5.2
Initial start-up and basic settings
Upon initial start-up:
•
Set the nominal absorbed current of the motor, see
on page 20
•
Set the P START and P STOP pressure values, see
Setting the P START and P STOP pressure
on page 21
•
Open the on-off valve on the delivery line
•
Start the pump unit in AUT mode
•
Close the valve: the P STOP pressure is reached and the pump unit stops.
NOTICE:
A correctly loaded diaphragm pressure tank must be installed, see
page 14.
NOTICE:
If the current is not set:
•
The unit remains in OFF mode
•
It is not possible to activate AUT mode
•
The overcurrent, short circuit and lack of water protection devices are deactivated.
5.2.1
OFF mode
OFF mode, pump unit stopped.
Action
Illustration
Press once to stop the pump unit