en - Original instructions
Genyo plus, Additional Installation, Operation and Maintenance Instructions
15
4.3.1
Guidelines for hydraulic connection
Refer to the representative hydraulic diagrams; see the figures below.
Figure 1: Installation with single pump unit
Figure 2: Installation of the booster set
Position
number
Description
Position
number
Description
1
Pump unit
5
Check valve
2
Diaphragm pressure tank
≥
24 l (6.3 US gal)
6
Genyo plus unit
3
Electric panel
7
Pressure gauge
4
On-off valve
8
Drain tap
1.
Remove any welding residues, deposits and impurities in the pipes that could damage the
unit.
2.
Install an on-off valve between the piping and the unit.
3.
Install an on-off valve on the suction side and another on the delivery side of the pump unit.
4.
Install a check valve between the unit and the pump unit.
5.
Install a pressure gauge for the unit.
6.
Install one or more diaphragm expansion tanks to limit the number of starts of the pump
unit.