en - Original instructions
Genyo plus, Additional Installation, Operation and Maintenance Instructions
31
9
Technical Information
9.1
Operating data and conditions
Data
Description
Input frequency
50/60 Hz ± 2
Main supply
L - N
Nominal input voltage
110 to 230 VAC ± 10%
Maximum absorbed current AC in continuous duty S1
16 A, cosØ ≥ 0.6
Electric motor nominal power
0.37 to 2.2 kW
START pressure
0.05 to 0.7 MPa, 0.5 to 7 bar (7.3 to 102 psi)
STOP pressure
0.1 to 0.8 MPa, 1 to 8 bar (14.5 to 116 psi)
Maximum differential
0.75 MPa, 7.5 bar (109 psi)
Minimum differential
0.05 MPa, 0.5 bar (7.3 psi)
Maximum pressure PN
0.8 MPa, 8 bar (116 psi)
Fluid connection
Rp ¼”
Weight
0.4 kg (0.88 lb)
EMC (Electro Magnetic Compatibility)
See Declarations on page 33
Protection class
IP 55, protect the product against rain and direct sunlight
Relative air humidity, place of operation and storage
5% to 95%
Storage temperature
-25 to 65°C (-13 to 149°F)
Ambient operating temperature
0 to 50°C (32 to 122°F)
Water temperature
0 to 40°C (32 to 104°F)
9.2
Dimensions
G
eny
op_
M
0024_
A_
sc
Rp 1/4”
75 m
m
(2,
95 i
n)
112 mm (4,4 in)