PREPARING FOR INSTALLATION

Inspect the pump and the motor assembly for shipping 

damage.

Insure that you have all of the parts required for a proper 

installation. See component lists for different system 

types. There are shallow well, convertible shallow well, 

convertible deep well – twin pipe, convertible deep 

well-packer, vertical deep well-twin pipe, vertical deep 

well-packer, and booster systems. 

See Typical Installation 

Drawings and Chart 1

.

Check power supply voltage and select motor voltage. 

Goulds ½ hp Jet pumps are factory pre-wired for 115 

volts while ¾ hp and larger are pre-wired for 230 volts. 

Motors from ½ hp to 1½ hp can operate on either 115 or 

230 volts. The 2 hp motors operate only on 230 volts. 

See 

Fig. 7

.

Select a site where the pump and tank will not freeze. 

The pump must be within 4' of the tank to prevent switch 

chatter. There should be no filters or valves, other than a 

wide open gate valve, between the pump and tank. Fluid 

temperature must not exceed 140

°

 F (60

°

C). The pump 

should be fixed rigidly to its support to prevent move

-

ment.

GENERAL INFORMATION - PIPING

Always follow state and local plumbing codes. Goulds 

Water Technology does not sell or specify pipe types or 

materials, consult with your pipe supplier to determine 

the best pipe for your installation. Pipes can be threaded, 

glued, soldered, or clamped to available fittings and 

adapters. If using poly pipe with barbed connectors we 

suggest you double clamp all fittings to prevent air leaks. 

It is very important to eliminate high spots and dips in 

suction piping as they will trap air and make the system 

very hard to prime. Never route the piping up above and 

then down to the pump suction. Suction piping should 

be either straight from the well to the pump or should 

slope upward to the pump. Pumps do not “hold” prime, 

piping systems and check valves do. Go to the specific 

section for your system type.

SHALLOW WELL INSTALLATION

 - 

start here

Suction Piping

The suction pipe should be at least as large as 

the pump suction, typically 1¼". Use of smaller 

pipe increases friction loss and increases ef-

fective suction lift. This will reduce flow and 

pressure. On offsets over 50' we recommend 

using pipe larger than the pump suction. This 

will reduce friction loss and improve performance.

Install a foot valve on the end of your drop pipe if the well 

is 2" or larger. Lower the drop pipe with foot valve into 

the well. It is best to keep it at least 5' off the bottom of a 

clean well. If you set it lower you increase the chance of 

pulling debris into the screen or into the pump.

On sand points or driven wells you can install an in-line 

check valve near the well head or at the pump and use 

the well casing as the suction pipe. The closer the check 

valve is to the well the easier the system will prime. 

To prevent over pumping a low yield well you can 

throttle a jet pump using a ball valve in the suction line. 

You should install a compound pressure/vacuum gauge 

between the well and the valve. Do not throttle to more 

than 22" Hg (25' lift).

In areas where freezing occurs make the transition from 

vertical to horizontal below the frost line using a pitless 

adapter, consult with your plumbing supplier for pitless 

adapter information. In some areas they use a well seal 

and a 90

°

 elbow.

We recommend not using filters on the suction side of 

a jet pump. Dirty filters increase the effective suction lift 

on the pump and can starve the pump of water. This 

will damage the impeller and diffuser which will affect 

performance.

Install Shallow Well Adapter On Convertible Pump

Unpack the Goulds Water Technology “Shallow Well 

Adapter”. Insure that the nozzle is installed in the adap-

ter. Screw the venturi (long black tube) into the adapter. 

Install the gasket and bolt the adapter to the front of the 

pump using the four bolts provided. Tighten the bolts 

evenly to insure proper sealing and alignment of the 

venturi to the impeller. Do not over tighten the bolts. 

See 

Chart 2

.

Shallow Well Pump – jet is built-in, proceed 

to next step.

Attach Suction Piping To Pump

Install a barbed adapter into the 1¼" pump 

suction if using poly pipe and double clamp 

the fitting. 

OR

Thread a pipe nipple and union into the suction port to 

make a threaded pipe connection. Make sure the union is 

clean and well seated. Any air leak will ruin performance 

and the pump will not make pressure!

Discharge Piping

Install a tee or cross tee in the pump discharge. (They 

are not supplied with the pump!) Install a pipe plug or a 

pressure gauge into a reducer bushing in the top port of 

the tee. This will be used as the priming port. 

Cross Tee -

 the discharge line to the home attaches to 

one port and the tank attaches to the other. This is called 

an Off-Line Tank installation.

Tee -

 you can use one line to supply the house with the 

tank tee installed off the line. This is called an On-Line 

Tank Installation and is most common.

Note:

 Goulds Water Technology HydroPro Water System 

tanks are shipped with a tank installation guide. Please 

refer to it for more detailed tank instructions.

Do not place valves or filters between the pump and 

tank, other than a fully open gate valve or “full port” ball 

valve. The most common ball valves are not full port! 

Most valves and filters will create excessive friction loss 

and cause “switch chatter”. Switch chatter is a rapid 

On-Off cycling of not only the pressure switch but also 

the motor. It will burn the points in the switch, the motor 

Hazardous pressure can
cause personal injury or
property damage.

WARNING

Hazardous pressure can
cause personal injury or
property damage.

WARNING

PREPARING FOR INSTALLATION

GENERAL INFORMATION - PIPING

SHALLOW WELL INSTALLATION

Summary of Contents for Goulds J Series

Page 1: ...Jet Pumps INSTALLATION OPERATION AND TROUBLESHOOTING MANUAL INSTRUCTION MANUAL IM102R11...

Page 2: ...ng orsystemtoapressurehigherthanthe tank smaximumpressurerating Thiswilldamage thetank voidsthewarrantyandmaycreateaserious hazard Protecttanksfromexcessivemoistureand sprayasitwillcausethetanktorusta...

Page 3: ...e are two types of deep well jet assemblies twin pipe and packer systems Deep well pumps come in both vertical and horizontal designs and in single and multi stage models See Typical Installation Draw...

Page 4: ...eck valve is to the well the easier the system will prime To prevent over pumping a low yield well you can throttle a jet pump using a ball valve in the suction line You should install a compound pres...

Page 5: ...on Using smaller than recommended pipe may reduce gpm output The longer the pipe the worse the affect Install Packer Assembly To ease installation soak the 2 or 3 packer assembly in warm water to make...

Page 6: ...AVC to replenish air lost through absorption The AVC requires connection to a vacuum port on the pump The suction side of the AVC must have a minimum 3 vacuum for 15 seconds when the pump starts Foll...

Page 7: ...goes for a 230 volt hook up either wire can go on either Line terminal Re install the switch cover NOTE Motor voltage is NOT changed in the pressure switch See Fig 7 in Technical Data Check to insure...

Page 8: ...P3 53 3 27 30 70 AV22 and JDW FT5B 48 4 40 70 110 FP3 54 3 30 70 110 FT4B 44 4 31 30 60 FP2 48 2 35 30 60 AWJ2 FT4B 43 4 33 60 80 FP2 43 2 36 60 100 AV22KIT J10 FT4B 18 4 35 80 110 AV22 and JDW FT5B 4...

Page 9: ...DEPTH JET WELL CONTROL VALVE DEPTH PACKER CONTROL VALVE ASSEMBLY DIAMETER SETTING PSI TO JET ASSEMBLY DIAMETER SETTING PSI TO JET ADAPTER see fig 4 FT3 09 3 30 30 50 FP2 13 2 30 30 50 FT4B 13 4 30 30...

Page 10: ...48C04A06 115 230 1 1 6 12 6 6 3 990 25 15 SFJ05860 JRS7 JRD7 JB07 C48C05A06 115 230 1 1 5 14 8 7 4 1200 30 15 SFJ06860 JRS10 JRD10 JB10 C48C06A06 1 115 230 1 1 4 16 2 8 1 1400 30 20 Effective July 199...

Page 11: ...ess than pump capacity throttle a ball valve in suction line do not exceed 22 Hg to reduce pump capacity USE OF TAILPIPE ON DEEP WELL JET PUMPS If the capacity of a deep well jet pump exceeds the well...

Page 12: ...method or means of repair or replacement Buyer s failure to comply with Seller s repair or replacement directions shall terminate Seller s obligations under this Warranty and render this Warranty voi...

Page 13: ...Bombas de Inyecci n MANUAL DE INSTALACI N OPERACI N E IDENTIFICACI N Y RESOLUCI N DE PROBLEMAS MANUAL DE INSTRUCCI N IM102R11...

Page 14: ...cedemasiadoeltanque las tuber asoelsistemaaunapresi nsuperiorala clasificaci ndepresi nm ximadeltanque Elhacerloda ar eltanque anulalagarant aypuedecrearunpeligrograve Protejaalostanquescontrahumedady...

Page 15: ...profundos para elevaciones de m s de 25 pies y deben tener dos tuber as que vayan al pozo Hay dos tipos de conjuntos de inyecci n para pozos profundos los sistemas de tubo doble y los sistemas de obtu...

Page 16: ...ra impedir bombear en exceso un pozo de baja producci n usted puede estrangular una bomba de inyecci n con una v l vula de bola en la l nea de succi n Usted debe instalar un indicador compuesto de pre...

Page 17: ...n como los gpm disminuir n La bomba puede perder cebado f cil mente durante el bombeo debido a la restricci n Si se utiliza tuber a m s peque a que la recomendada podr a reducirse la salida de gpm Mie...

Page 18: ...nstalan de la misma mane ra que los tanques precargados excepto que requieren un control de volumen de aire AVC para reponer el aire perdido por absorci n El control de volumen de aire requiere una co...

Page 19: ...si n Co necte los alambres de la fuente de alimentaci n ya sea 115 230 dependiendo de la tensi n del motor a las terminales de l nea del interruptor por ca da de presi n Conecte el alambre verde o ala...

Page 20: ...0 90 AV22KIT J7 FT4B 18 4 30 90 110 o FT5B 47 4 28 30 70 FP3 53 3 27 30 70 AV22 and JDW FT5B 48 4 40 70 110 FP3 54 3 30 70 110 FT4B 44 4 31 30 60 FP2 48 2 35 30 60 AWJ2 FT4B 43 4 33 60 80 FP2 43 2 36...

Page 21: ...RADOR FT3 09 3 30 30 50 FP2 13 2 30 30 50 FT4B 13 4 30 30 50 AV15 JRD5 FT4B 31 4 30 30 70 FP2 31 2 30 30 60 AWJ2 o FT4B 08 4 30 60 90 FP2 08 2 30 60 80 AV22KIT FT5B 14 4 30 70 90 FT4B 14 4 27 30 60 FP...

Page 22: ...B07 C48C05A06 115 230 1 1 5 14 8 7 4 1200 30 15 SFJ06860 JRS10 JRD10 JB10 C48C06A06 1 115 230 1 1 4 16 2 8 1 1400 30 20 Fecha de vigencia julio de 1998 230 V nicamente DATOS T CNICOS Fig 7 PROCEDIMIEN...

Page 23: ...dad de la bomba estrangule una v lvula de bola en la l nea de succi n sin exceder 22 pulg de Hg para reducir la capacidad de la bomba USO DEL TUBO DE ASPIRACI N EN BOMBAS DE INYECCI N PARA POZOS PROFU...

Page 24: ...o reemplazo ser a total discreci n del Vendedor Si el Comprador no cumple con las instrucciones de reparaci n o reemplazo del Vendedor esto rescindir las obligaciones del Vendedor conforme a la presen...

Page 25: ...Pompes Jet MANUEL D INSTALLATION D UTILISATION ET DE D PANNAGE MANUEL D UTILISATION IM102R11...

Page 26: ...meetler servoir nejamaisutiliser unepressionexc dantlapressionnominale maximaledecedernier afindenepasl endommager annulerla garantieniconstituerungravedanger Prot gerler servoirdes claboussuresetdes...

Page 27: ...aux descendant dans le puits Il en existe deux types tuyaux jumel s ou tuyaux concentriques Les pompes pour puits profonds sont offertes en ver sions horizontales ou verticales multi tag es ou non Voi...

Page 28: ...la cr pine ou dans la pompe Dans le cas des installations pointe filtrante ou en puits tubulaires on peut poser un clapet de non retour pr s de la t te de puits ou de la pompe et utiliser le cuvelage...

Page 29: ...r le guide Ne pas poser de robinets de soupapes ni de filtres entre la pompe et le r servoir sauf s il s agit d un robinet vanne grand ouvert ou d un robinet tournant sph rique passage int gral La plu...

Page 30: ...its profonds Amorcer un syst me pour puits profonds signifie remplir d eau les tuyaux d aspiration et d alimentation en eau motrice ainsi que la pompe Les pompes multi tag es ou non pour puits profond...

Page 31: ...FONCTIONNER LA POMPE SEC CAR CELA L ENDOMMAGE RAIT ET ANNULERAIT LA GARANTIE ON DOIT TOUJOURS VERROUILLER LE DISJONCTEUR OU LE SECTIONNEUR SELON LE CAS DU CIRCUIT LEC TRIQUE EN POSITION OUVERTE HORS...

Page 32: ...6 3 34 30 60 J15 FT5B 11 4 40 70 140 FP3 18 3 34 60 90 AV22KIT FP3 21 3 34 90 150 AV22 et JDW FP3 24 3 39 100 170 FT4B 48 4 37 30 70 FP2 51 30 70 SJ07 et FT4B 47 4 40 70 90 FP2 50 2 40 70 90 AWD2 HSJ0...

Page 33: ...90 110 AV22 et JDW FT5B 47 4 27 30 70 S O FT5B 48 4 30 70 110 FT4B 44 4 31 30 60 FP2 48 2 35 30 60 FT4B 43 4 33 60 80 FP2 43 2 36 60 100 AWJ2 AV22KIT JRD10 FT4B 18 4 35 80 110 AV22 et JDW FT5B 49 4 28...

Page 34: ...C48C04A06 115 230 1 1 6 12 6 6 3 990 25 15 SFJ05860 JRS7 JRD7 JB07 C48C05A06 115 230 1 1 5 14 8 7 4 1200 30 15 SFJ06860 JRS10 JRD10 JB10 C48C06A06 1 115 230 1 1 4 16 2 8 1 1400 30 20 230 V seulement p...

Page 35: ...ire le d bit de celle ci l aide d un robinet tournant sph rique pos sur le tuyau d aspiration et r gl pour augmenter la d pression qui ne doit cependant pas d passer 22 po de Hg EMPLOI D UN TUYAU RALL...

Page 36: ...de r paration ou de remplacement Le non respect de l Acheteur de se conformer aux directives de r paration ou de remplacement du Vendeur mettra fin aux obligations du Vendeur sous cette Garantie et a...

Reviews: