Xylem Goulds J Series Instruction Manual Download Page 2

2

Table of Contents

SUBJECT 

PAGE

Selecting the Correct Jet Pump System ............................................................................................................................ 3
Preparing for Installation ..................................................................................................................................................... 4
General Information - Piping .............................................................................................................................................. 4
Shallow Well Installation ..................................................................................................................................................... 4 
Deep Well Twin Pipe ............................................................................................................................................................ 5
Deep Well Packer System ................................................................................................................................................... 5
Deep Well Discharge Piping .............................................................................................................................................. 5
All Systems ............................................................................................................................................................................ 6
Booster Systems ................................................................................................................................................................... 7
Seasonal Service .................................................................................................................................................................. 7
Recommended Deep Well Jet Assemblies and Control Valve Settings ....................................................................8-9
Shallow Well Jet Assemblies For Convertible Pumps ..................................................................................................... 9
Technical Data .............................................................................................................................................................. 10-11
Troubleshooting ................................................................................................................................................................. 12
Goulds Water Technology Limited Warranty ................................................................................................................. 12

Table of Contents

All electrical work must be performed 

by a qualified technician. Always follow 

the National Electrical Code (NEC), or the Canadian 

Electrical Code, as well as all local, state and provincial 

codes. Code questions should be directed to your local 

electrical inspector. Failure to follow electrical codes and 

OSHA safety standards may result in personal injury or 

equipment damage. Failure to follow manufacturer’s 

installation instructions may result in electrical shock, fire 

hazard, personal injury or death, damaged equipment, 

provide unsatisfactory performance, and may void 

manufacturer’s warranty.

Standard units are not designed for use 

in hazardous liquids, or where flammable 

gases exist. Well must be vented per local codes. 

See 

specific pump catalog bulletins or pump nameplate for 

all agency Listings

.

Disconnect and lockout electrical power 

before installing or servicing any electrical 

equipment. Many pumps are equipped 

with automatic thermal overload protection which may 

allow an overheated pump to restart unexpectedly.

Never over pressurize the tank, piping 

or system to a pressure higher than the 

tank's maximum pressure rating. This will damage 

the tank, voids the warranty and may create a serious 

hazard.

Protect tanks from excessive moisture and 

spray as it will cause the tank to rust and 

may create a hazard. See tank warning labels and IOM 

for more information.

This appliance is not intended for use 

by persons (including children) with 

reduced physical, sensory or mental capabilities, or lack 

of experience and knowledge, unless they have been 

given supervision or instruction concerning use of the 

appliance by a person responsible for their safety.

Children should be supervised to ensure 

that they do not play with the appliance.

WARNING

WARNING

WARNING

Important notice: Read safety instructions before 

proceeding with any wiring

SAFETY INSTRUCTIONS                  

TO AVOID SERIOUS OR FATAL PERSONAL  

INJURY OR MAJOR PROPERTY DAMAGE, READ 

AND FOLLOW ALL SAFETY INSTRUCTIONS IN 

MANUAL AND ON PUMP.
THIS MANUAL IS INTENDED TO ASSIST IN THE 

INSTALLATION AND OPERATION OF THIS UNIT 

AND MUST BE KEPT WITH THE PUMP.

This is a 

SAFETY ALERT SYMBOL

When you see this symbol on the 

pump or in the manual, look for one 

of the   following signal words and 

be alert to the potential for personal 

injury or property damage.
Warns of hazards that 

WILL

 cause 

serious personal injury, death or major 

property damage.
Warns of hazards that 

CAN

 cause 

serious personal injury, death or major 

property damage.
Warns of hazards that 

CAN

 cause per-

sonal injury or property damage.

NOTICE:  INDICATES SPECIAL INSTRUCTIONS 

WHICH ARE VERY IMPORTANT AND MUST BE 

FOLLOWED.
THOROUGHLY REVIEW ALL INSTRUCTIONS 

AND WARNINGS PRIOR TO PERFORMING ANY 

WORK ON THIS PUMP.
MAINTAIN ALL SAFETY DECALS.

DANGER

CAUTION

WARNING

WARNING

WARNING

WARNING

WARNING

Summary of Contents for Goulds J Series

Page 1: ...Jet Pumps INSTALLATION OPERATION AND TROUBLESHOOTING MANUAL INSTRUCTION MANUAL IM102R11...

Page 2: ...ng orsystemtoapressurehigherthanthe tank smaximumpressurerating Thiswilldamage thetank voidsthewarrantyandmaycreateaserious hazard Protecttanksfromexcessivemoistureand sprayasitwillcausethetanktorusta...

Page 3: ...e are two types of deep well jet assemblies twin pipe and packer systems Deep well pumps come in both vertical and horizontal designs and in single and multi stage models See Typical Installation Draw...

Page 4: ...eck valve is to the well the easier the system will prime To prevent over pumping a low yield well you can throttle a jet pump using a ball valve in the suction line You should install a compound pres...

Page 5: ...on Using smaller than recommended pipe may reduce gpm output The longer the pipe the worse the affect Install Packer Assembly To ease installation soak the 2 or 3 packer assembly in warm water to make...

Page 6: ...AVC to replenish air lost through absorption The AVC requires connection to a vacuum port on the pump The suction side of the AVC must have a minimum 3 vacuum for 15 seconds when the pump starts Foll...

Page 7: ...goes for a 230 volt hook up either wire can go on either Line terminal Re install the switch cover NOTE Motor voltage is NOT changed in the pressure switch See Fig 7 in Technical Data Check to insure...

Page 8: ...P3 53 3 27 30 70 AV22 and JDW FT5B 48 4 40 70 110 FP3 54 3 30 70 110 FT4B 44 4 31 30 60 FP2 48 2 35 30 60 AWJ2 FT4B 43 4 33 60 80 FP2 43 2 36 60 100 AV22KIT J10 FT4B 18 4 35 80 110 AV22 and JDW FT5B 4...

Page 9: ...DEPTH JET WELL CONTROL VALVE DEPTH PACKER CONTROL VALVE ASSEMBLY DIAMETER SETTING PSI TO JET ASSEMBLY DIAMETER SETTING PSI TO JET ADAPTER see fig 4 FT3 09 3 30 30 50 FP2 13 2 30 30 50 FT4B 13 4 30 30...

Page 10: ...48C04A06 115 230 1 1 6 12 6 6 3 990 25 15 SFJ05860 JRS7 JRD7 JB07 C48C05A06 115 230 1 1 5 14 8 7 4 1200 30 15 SFJ06860 JRS10 JRD10 JB10 C48C06A06 1 115 230 1 1 4 16 2 8 1 1400 30 20 Effective July 199...

Page 11: ...ess than pump capacity throttle a ball valve in suction line do not exceed 22 Hg to reduce pump capacity USE OF TAILPIPE ON DEEP WELL JET PUMPS If the capacity of a deep well jet pump exceeds the well...

Page 12: ...method or means of repair or replacement Buyer s failure to comply with Seller s repair or replacement directions shall terminate Seller s obligations under this Warranty and render this Warranty voi...

Page 13: ...Bombas de Inyecci n MANUAL DE INSTALACI N OPERACI N E IDENTIFICACI N Y RESOLUCI N DE PROBLEMAS MANUAL DE INSTRUCCI N IM102R11...

Page 14: ...cedemasiadoeltanque las tuber asoelsistemaaunapresi nsuperiorala clasificaci ndepresi nm ximadeltanque Elhacerloda ar eltanque anulalagarant aypuedecrearunpeligrograve Protejaalostanquescontrahumedady...

Page 15: ...profundos para elevaciones de m s de 25 pies y deben tener dos tuber as que vayan al pozo Hay dos tipos de conjuntos de inyecci n para pozos profundos los sistemas de tubo doble y los sistemas de obtu...

Page 16: ...ra impedir bombear en exceso un pozo de baja producci n usted puede estrangular una bomba de inyecci n con una v l vula de bola en la l nea de succi n Usted debe instalar un indicador compuesto de pre...

Page 17: ...n como los gpm disminuir n La bomba puede perder cebado f cil mente durante el bombeo debido a la restricci n Si se utiliza tuber a m s peque a que la recomendada podr a reducirse la salida de gpm Mie...

Page 18: ...nstalan de la misma mane ra que los tanques precargados excepto que requieren un control de volumen de aire AVC para reponer el aire perdido por absorci n El control de volumen de aire requiere una co...

Page 19: ...si n Co necte los alambres de la fuente de alimentaci n ya sea 115 230 dependiendo de la tensi n del motor a las terminales de l nea del interruptor por ca da de presi n Conecte el alambre verde o ala...

Page 20: ...0 90 AV22KIT J7 FT4B 18 4 30 90 110 o FT5B 47 4 28 30 70 FP3 53 3 27 30 70 AV22 and JDW FT5B 48 4 40 70 110 FP3 54 3 30 70 110 FT4B 44 4 31 30 60 FP2 48 2 35 30 60 AWJ2 FT4B 43 4 33 60 80 FP2 43 2 36...

Page 21: ...RADOR FT3 09 3 30 30 50 FP2 13 2 30 30 50 FT4B 13 4 30 30 50 AV15 JRD5 FT4B 31 4 30 30 70 FP2 31 2 30 30 60 AWJ2 o FT4B 08 4 30 60 90 FP2 08 2 30 60 80 AV22KIT FT5B 14 4 30 70 90 FT4B 14 4 27 30 60 FP...

Page 22: ...B07 C48C05A06 115 230 1 1 5 14 8 7 4 1200 30 15 SFJ06860 JRS10 JRD10 JB10 C48C06A06 1 115 230 1 1 4 16 2 8 1 1400 30 20 Fecha de vigencia julio de 1998 230 V nicamente DATOS T CNICOS Fig 7 PROCEDIMIEN...

Page 23: ...dad de la bomba estrangule una v lvula de bola en la l nea de succi n sin exceder 22 pulg de Hg para reducir la capacidad de la bomba USO DEL TUBO DE ASPIRACI N EN BOMBAS DE INYECCI N PARA POZOS PROFU...

Page 24: ...o reemplazo ser a total discreci n del Vendedor Si el Comprador no cumple con las instrucciones de reparaci n o reemplazo del Vendedor esto rescindir las obligaciones del Vendedor conforme a la presen...

Page 25: ...Pompes Jet MANUEL D INSTALLATION D UTILISATION ET DE D PANNAGE MANUEL D UTILISATION IM102R11...

Page 26: ...meetler servoir nejamaisutiliser unepressionexc dantlapressionnominale maximaledecedernier afindenepasl endommager annulerla garantieniconstituerungravedanger Prot gerler servoirdes claboussuresetdes...

Page 27: ...aux descendant dans le puits Il en existe deux types tuyaux jumel s ou tuyaux concentriques Les pompes pour puits profonds sont offertes en ver sions horizontales ou verticales multi tag es ou non Voi...

Page 28: ...la cr pine ou dans la pompe Dans le cas des installations pointe filtrante ou en puits tubulaires on peut poser un clapet de non retour pr s de la t te de puits ou de la pompe et utiliser le cuvelage...

Page 29: ...r le guide Ne pas poser de robinets de soupapes ni de filtres entre la pompe et le r servoir sauf s il s agit d un robinet vanne grand ouvert ou d un robinet tournant sph rique passage int gral La plu...

Page 30: ...its profonds Amorcer un syst me pour puits profonds signifie remplir d eau les tuyaux d aspiration et d alimentation en eau motrice ainsi que la pompe Les pompes multi tag es ou non pour puits profond...

Page 31: ...FONCTIONNER LA POMPE SEC CAR CELA L ENDOMMAGE RAIT ET ANNULERAIT LA GARANTIE ON DOIT TOUJOURS VERROUILLER LE DISJONCTEUR OU LE SECTIONNEUR SELON LE CAS DU CIRCUIT LEC TRIQUE EN POSITION OUVERTE HORS...

Page 32: ...6 3 34 30 60 J15 FT5B 11 4 40 70 140 FP3 18 3 34 60 90 AV22KIT FP3 21 3 34 90 150 AV22 et JDW FP3 24 3 39 100 170 FT4B 48 4 37 30 70 FP2 51 30 70 SJ07 et FT4B 47 4 40 70 90 FP2 50 2 40 70 90 AWD2 HSJ0...

Page 33: ...90 110 AV22 et JDW FT5B 47 4 27 30 70 S O FT5B 48 4 30 70 110 FT4B 44 4 31 30 60 FP2 48 2 35 30 60 FT4B 43 4 33 60 80 FP2 43 2 36 60 100 AWJ2 AV22KIT JRD10 FT4B 18 4 35 80 110 AV22 et JDW FT5B 49 4 28...

Page 34: ...C48C04A06 115 230 1 1 6 12 6 6 3 990 25 15 SFJ05860 JRS7 JRD7 JB07 C48C05A06 115 230 1 1 5 14 8 7 4 1200 30 15 SFJ06860 JRS10 JRD10 JB10 C48C06A06 1 115 230 1 1 4 16 2 8 1 1400 30 20 230 V seulement p...

Page 35: ...ire le d bit de celle ci l aide d un robinet tournant sph rique pos sur le tuyau d aspiration et r gl pour augmenter la d pression qui ne doit cependant pas d passer 22 po de Hg EMPLOI D UN TUYAU RALL...

Page 36: ...de r paration ou de remplacement Le non respect de l Acheteur de se conformer aux directives de r paration ou de remplacement du Vendeur mettra fin aux obligations du Vendeur sous cette Garantie et a...

Reviews: