KPM(T) Series Flat Panel Industrial Monitor
Appendix A – Technical Specifications
53
143448 (
D
)
Environmental Specifications
Table A - 2 lists the environmental specifications for the KPM(T) monitors.
Table A - 2. 5012KPM(T) & 5015KPM(T) Environmental Specifications
Characteristic
Specification
Temperature
Operating
Non-operating
0° to 50° C (32° to 122° F)
-20° to 60° C (-4° to 140° F)
Humidity
Operating
Non-operating
20% to 80% RH, non-condensing
20% to 80% RH, non-condensing
Altitude*
Operating
Non-operating
Sea level to 10,000 feet (3,048 m)
Sea level to 40,000 feet (12,192 m)
Vibration 5-2000 Hz
Operating
Non-operating
0.006” (0.15 mm) peak to peak displacement
1.0g maximum acceleration
0.015” (0.38 mm) peak to peak displacement
2.5g maximum acceleration
Shock
Operating
Non-operating
15g peak acceleration, 11 msec duration, ½ sine wave
30g peak acceleration, 11 msec duration, ½ sine wave
* Consistent with internal component specifications