KPM(T) Series Flat Panel Industrial Monitor
Chapter 3 – Monitor Settings
34
143448 (
D
)
Figure 3-5. Position submenu
Figure 3-6 shows the three options available in the Image submenu: Phase;
Horizontal size; and Auto phase
Figure 3-6. Image submenu
Figure 3-7 explains the three options available in the Miscellaneous submenu: Load
Default; OSD Timeout; OSD position.
Figure 3-7. Miscellaneous submenu
,
$ "!
To reset the factory default settings on your monitor, follow these steps.
1. Navigate to the Miscellaneous menu and highlight
Load Default
.
2. Press SELECT to enter submenu, which will ask you to choose yes or no.
3. Press the INC key to highlight
yes,
and press SELECT to enable your choice.
4. The default settings will be loaded as the submenu is exited.
Analog RGB Interface Specifications
Listed below are the Analog RGB Interface specifications.
•
Based on VESA standard, separate analog RGB
•
0.7Vp-p positive true typically
•
Input range: 0.5 to 1.0Vp-p typical with terminal resistance of 75
Ω
•
H sync signal input: TTL level, negative true or positive true
•
V sync signal input: TTL level, negative true or positive true
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com