Power Supply
The power supply provides 80 watts of output throughout the system’s temperature
range. The expansion power is limited as shown in the following table.
Available Expansion Current
Voltage
Available Current
AHIP4+ (5x86
processors)
a
AHIP6+ (Celeron and
Pentium II processors)
b
+5 VDC
6.17A
+3.3 9A
+12 VDC
1.88A
+5 6A
-12 VDC
0.71A
+12 1.5A
-12 .45A
a
Total expansion power not to exceed 46 watts
b
Total expansion power not to exceed 48 watts
Hazardous Locations Installations
Xycom Automation designed the systems to meet the requirements of Class I,
Division 2 Hazardous Locations applications. Division 2 locations are those