Chapter 3-Installation
3-7
Power Panel
Figure 3-5. Bottom Panel with Power Connector and External Floppy Connector
Feature
Description
Power Connector
This is a three-pin connector. Refer to the special hazardous
location installation instructions later in this chapter.
External Floppy Drive Connector
This is a 26-pin connector.
Product ID Label
The product ID label is located on the bottom panel
Fan and Filter
The filter can be replaced or removed for cleaning. See Chapter 5
for details on the fan filter assembly.
Preparing the System
Read this chapter first, comply with all the safety requirements, then mount the unit
according to the following instructions.
1.
Locate a position that meets the required specifications
2.
Do a panel cutout. The dimensions are given in this chapter.
3.
Install optional equipment following the instructions in
Installing Internal
Hardware Options
and
Installing External Hardware Options
in this chapter.
4.
Create the power cable. Refer to the
Creating a Power Cable
section in this
chapter.
5.
Mount the system and properly secure the unit into the panel. See
Installing the
System
section in this chapter.
6.
Attach one end of the power cord to the power receptacle and the other end to a
properly grounded 115/230 VAC, 50-60 Hz outlet or a 24 VDC outlet,
whichever applies (refer to the Hazardous Location Installations section later in
this chapter).