Procedure
Power off the unit
Apply power while pressing the reset button until the power LED
turns on
(Approx. after 10 secs)
Release the reset button. The Unit will boot from FW1, with
factory defaults
Revert to FW0 -
All encoder settings will be deleted including licenses. The
encoder will switch to
base version firmware FW0
. Network parameters will
be lost. Use the
XVC management tool
to setup the network parameters.
After network parameters are set, the user can upgrade the firmware to a
new version
Procedure
Power off the unit
Apply power while pressing the reset button until the power LED
flashes slowly
(Approx after 20 secs)
Release the reset button. The Unit will boot, with FW0 as the active
firmware
Full recovery