background image

www.XtremeAirUsa.com

                                                                    PAGE 

11

 

 

    TROUBLE SHOOTING 

 

1. 

If the range hood or lights does not operate after installation: 

 

Check if the range hood has been plugged in, make sure that all power has been turned back ON, the 
fuse is not blown and all electrical wiring is properly connected. 

 

Swap out light assembly to working ones to deter• mine whether it is caused by defective bulbs. See 

replacing the light bulbs 

on Page 13. 

 

2. The range hood vibrates when the blower is on: 

 

The range hood might not have been secured properly on to the ceiling or wall. 

 

Check if the motor is secured in place.    If not, then tighten the motor in place. Check if the blower 
wheel is a damaged.       

 

3. The blower or fan seems weak:   

 

Check that the duct sized used is at least 6”.    Range hood WILL NOT function efficiently with 
insufficient duct size & loosely secured.   

 

Check if duct is clogged or if damper unit (half-circular flapper) is not installed correctly or opening 
properly. A tight mesh on a side wall cap unit might also cause restriction to the air flow. 

 

4. The lights work but the blower is not spinning at all, is stuck or is rattling. 

 

The blower might be

 jammed or scraping the bottom due to shipping damage.                   

Please contact us immediately.

 

 

The motor is defective, possibly seized - change the motor.

 

 

5.

 The hood is not venting out properly

:  

 

Make sure the distance between the stove top and the bottom of the hood is within 26” and 30” in distance. 

Due to different ceiling height configurations, recommended height may not be applicable.

 

 

Reduce the number of elbows and length of duct work. Check if all joints are properly connected, sealed, 
and taped.   

 

Make sure the power is on high speed for heavy cooking

 

 

6. The hood is noiser than normal 

 

The duct is not secure and causes vibration

 

 

The smaller duct size than required is using

 

 

7. Control panel is not active 

 

Check to make sure the auto function is not on 

 

8. Remote control is not working 

 

Check to make sure the plastic film was removed.

 

 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

 

1. Make sure the range hood is unplugged or turn OFF breaker.   
2. Use the small flat crew driver to lift any where around the 
outsider ring as show in below picture Arrow. 
3. Install new light bulb 
4. Put back the light set by press it in. 
5. Turn ON breaker and range hood to test for operation. 

 

 

REPLACING THE LIGHT BULB 

13 

12 

Summary of Contents for PRO-X PX10-U30

Page 1: ...1 Under Cabinet Range Hood IMPORTANT READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL INDOOR USE ONLY PRO X SERIES INSTALLATION GUIDE USER S MANUAL R130 PX10 U30 R136 PX10 U36 PX11 U30 PX11 U36 R230 PX12 U30 R236 PX12 U36 Model ...

Page 2: ...o not store flammable or explosive materials in adjacent cabinets or surrounding areas Disclaimer The manufacturer and or distributor reseller decline all responsibility in the event of failure to ob serve the instructions provided for installation maintenance and suitable use of the product The manufacturer and or distributor reseller shall NOT be responsible for any injury due to negligence and ...

Page 3: ...iring must be properly installed insulated and grounded Before servicing or cleaning unit turn power OFF and un plugged OPERATION Use high settings on cooking range only when necessary Keep all fan baffle spaces filter grease tunnel oil container and grease laden surfaces clean Grease should not be allowed to accumulate on fan baffle spaces filter grease tunnel and oil container Never allow the fi...

Page 4: ...ystem must have a damper If roof or wall cap has a damper do not use damper supplied for some models only with the range hood For the most efficient quiet operation A distance of 26 to 30 is recommended between stove top and the bottom of range hood It is recommended that the range hood be vented vertically through the roof through 8 or bigger vent work ALWAYS when possible reduce the number or tr...

Page 5: ...de ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances TOOL YOU WILL NEED Maker or pencil Stud finder Measuring tape Powered screwdriver or drill Flat Phillips screwdrivers Level Drill with 1 1 4 7 9 mm drill bits Jigsaw or keyhole saw PARTS SUPPLIED Baffle Filters 1 Instruction manual book 1 Rem...

Page 6: ... thick protective covering over counter top cook top or range to protect from damage or dirt TIP optional you can create a solid flat form by having 2 solids 2 3 block at both side of stove and a 3 4 1 plywood flat form above Figure 2 2 For installing under the cabinet with recessed bottom attach 4 inch wide wood filler strips not provided on each side Refer to below figure 3 3 Create access openi...

Page 7: ...ure A 5 From inside of the hood place screws into the exact center of each knockout holes 4 and secure to cabinet bottom Finish tightening all screws until secure Be careful when using electrical screwdriver damage to the range hood may occur Figure 6 7 Secure the hood by using 1 5 2 0 wood screws the screws are not provided screw through the back of hood to the studs use stub finder to find the s...

Page 8: ...tically after a period of inactivity A Activating Normal Blower Function B Activating Light Function C Activating Power Off Delay Function RIGHT a whole button is covered by a finger WRONG Only half of a button is covered by a finger RIGHT VS WRONG While the range hood is off Touch to start from lowest speed F1 Touch to start from Highest speed F4 Touch or again to change the blower speed as indic...

Page 9: ...tive timer reset 4 3 Blower motor is running light indicator 5 4 Shows current blower motor speed 1 4 6 5 Lights up when lights turned on 7 6 To turns ON OFF lights 8 8 Indicates the accumulated time the system is running 9 9 Indicates the length of time left for delay off function 10 10 Lights up when auto shutdown delay timer function is on While the machine is off touch Auto Function button to ...

Page 10: ...r off delay digital timer will begin to countdown when it reaches zero the blower motor will shut down G To clear cleaning reminder When blower motor starts to rotate cumulative running time will be shown in Power On Elapsed Digital Timer This timer icon flashes when 30 hours is up and reminds user to clean the baffle filters After cleaning the filters and when the motor is not in use touch and ho...

Page 11: ... work but the blower is not spinning at all is stuck or is rattling The blower might be jammed or scraping the bottom due to shipping damage Please contact us immediately The motor is defective possibly seized change the motor 5 The hood is not venting out properly Make sure the distance between the stove top and the bottom of the hood is within 26 and 30 in distance Due to different ceiling heigh...

Page 12: ...ool scoring pads which will scratch and damage the stainless steel surface For heavier soil use liquid degrease such as Formula 409 or Fantastic brand cleaner If hood looks splotchy stainless steel hood use a stainless steel cleaner to clean the surface of the hood Avoid getting cleaning solution onto or into the control panel Follow directions of the stainless steel cleaner CAUTION Do not leave o...

Reviews: