36
detection zone. After you completed the setup, please click ENTER button to exit current
setup. Do remember click save button to save current setup. If you click ESC button to exit
the region setup interface system will not save your zone setup.
Sensitivity: System supports 6 levels. The sixth level has the highest sensitivity.
Show message: System can pop up a message to alarm you in the local host screen if you
enabled this function.
Alarm upload: System can upload the alarm signal to the network (including alarm centre)
if you enabled current function.
Send email: System can send out email to alert you when alarm occurs.
MMS: Highlight the icon to enable this function. System can send out a message to the user
once an alarm occurs.
Period: Click set button, you can see an interface is shown as in
X306H306H306H
Figure 4-19
X
. Here you can
set for business day and non-business day. In
X307H307H307H
Figure 4-19
X
, click set button, you can see
an interface is shown as in
X308H308H308H
Figure 4-20. Here you can set your own setup for business day
and non-business day.
Anti-dither: Here you can set anti-dither time. If you input 10 seconds here, then the motion
detect signal will last for 10 seconds and then disappear. Please note, this function is for
motion detect only. It does not support camera masking and video loss.
Alarm output: when alarm occurred, system enables peripheral alarm devices.
Tour: Here you can enable tour function when alarm occurs. It is a one-window tour. Please
go to chapter 5.3.9 Display for tour interval setup.
Buzzer: Highlight the icon to enable this function. The buzzer beeps when an alarm occurs.
Please highlight icon
to select the corresponding function. After all the setups please click
save button, system goes back to the previous menu.
Note:
In motion detection mode, you can not use copy/paste to set channel setup since the video in
each channel may not be the same.
In
X309H309H309H
Figure 4-18
X
, you can left click mouse and then drag it to set a region for motion detection.
Click Fn to switch between arm/withdraw motion detection. After setting, click enter button to exit.
Figure 4-17