CAT5 System Settings
4.4.2.4
Parameters Settings
All the parameters of C5-IPC can be set through IP-Device. See IP-Device manual for detail.
4.4.2.5
Controller Concept
Controller in the system serves as the controlling center, it controls data communicating, audio
and video distribution. Of all the devices, Door station and C5-IPC can be set to be the controller.
Rules must be followed as below:
1)
There must be one and only one controller in the system.
2)
C5-IPC is designed to be the controller by default, and cannot be set to be non-controller
3)
Door station must be set to be non-controller when working with C5-IPC.
How to set Controller on door station:
- - - - - - - - - - - - - - - - - - - - - - - - - - -
2
- # S e t u p
3
- # M o n i t o r P r o g r a m
- - - - - - - - - - - - To o l s - - - - - - - - - -
5 - # O n l i n e M o n i t o r. . .
- - - - - - - - - - - - - - - - - - - - - - - - - - -
E X I T : # - 9 0 0 9
- - - - - - - - - - - - - - - - - - - - - - - - - - -
1 . D S S e r i a l N O .
2 . U n l o c k T i m i n g
4.
. C a r d M e m o r y
5.
. D o o r p l a t e M o d e . . .
7 . P a r a m e t e r s . . .
8 . I n s t a l l e r C o d e
9 . D e f a u l t . . .
- - - - - - - - - - - - - - - - - - - - - - - - - - -
P r e s s 1 ~ 9 t o s e l e c t
* B a c k
. . [ 1 ] [ 1 ]
D S S e r i a l N O .
[ - ]
0 : 1 D S S t a n d a l o n e
1 ~ 8 : M u l t i D S N O .
9 : C o m m o n D o o r S t a t i o n
( 0 ~ 9 )
* B a c k
# S a v e
V i d e o E n t r y S y s t e m
V i d e o E n t r y S y s t e m
V i d e o E n t r y S y s t e m
In standby mode, in-
put #9008+password
(66666666, by default)
On the keypad, input 1 to
enter DS Serial NO.
Input the number according
to the information, then # to
save the parameter
Notes:
1.
DS Serial NO. set to be 0, the door station serves as the controller
2.
DS Serial set to be from 1~8 to be non-controller, if there is no C5-MDS(only one
door station), the door station must be set to 1
3.
DS Serial NO. set to 9 to work as common door station