![XtendLan CAT-5 wired Technical Manual Download Page 32](http://html1.mh-extra.com/html/xtendlan/cat-5-wired/cat-5-wired_technical-manual_3710370032.webp)
Page 28
Chapter 2
CAT5 System Parts
1 2 3 4 5 6
LE
D2
01
LE
D2
02
LE
D2
03
LE
D2
04
•
PA204:
Reserved in normal status, for door
S2 0 1 PA202 PA204
LE D202 LE D203
station communication in test status
P A 201 PA203 LED201
LE D204
•
LED201:
Power indicator
•
LED202:
Reserved
•
LED203:
Picture saving indicator
•
LED204:
Picture play indicator
•
JWP101:
Power input, DC 24V
•
RS485:
PC port. To update the firmware
•
CN-NET:
RJ45 Network Port, connected to
O N
D I P
S2 0 1
PA2 0 1 PA2 0 2 PA2 0 3 PA2 0 4
C5-IMC
F M - SET
LAN
P- P+ P- P+
T/R- T/R+
•
FM-SET:
Video match switch
Specificatio n
•
Power supply:
DC24V
•
Standby current:
78mA
•
Working current:
135mA
•
Working temperature:
-10
0
C~40
0
C
•
Connection port:
RJ45
•
Dimensions:
140*150*60mm
JWP101 RS485 C N-NET FM-SET
2.3.4.7
Independent Access Controller: GP-ACS
GP-ACS is an independent access controller, used for the entrance without the need for door sta-
tion. Two locks and card readers can be connected to this device, so it can control two entrances
at the same time. GP-ACS can manage cards independently or through the PC in the network.
•
Tow doors control ports (card reader port, electric lock port and status test)
•
Lock release delay time setting
•
Lock type setting
•
Work status indicator
Parts and function
s
•
Power:
Power indicator, always ON while working
•
LINK:
Signal indicator, flicker means signal is transmitted in the bus line
•
IN-USE:
Status indicator, ON while working
Summary of Contents for CAT-5 wired
Page 1: ...CAT 5 video intercom system Technical guide...
Page 10: ......