![XtendLan CAT-5 wired Technical Manual Download Page 52](http://html1.mh-extra.com/html/xtendlan/cat-5-wired/cat-5-wired_technical-manual_3710370052.webp)
Page 48
Chapter 4
CAT5 System Settings
•
Installer Setup (Debug State->1#->1. Installer Setup->7. Parameters)
Three pages are available inside the parameters, press # to switch between different pages
Table 1
Item
Descriptions
Factory Set
1. Monitor Numbs
To set number of monitors that can monitor the door station
at the same time
[2]
2. Monitor Timing
The maximum monitoring time
[30]
3. Monitor & Talk
Enable/Disable talk function when monitoring
[1]:
Enable
4. Monitor & unlock
Enable/Disable unlock function when monitoring
[1]:
Enable
5.Wait Timing
Maximum wait time when making a call
[30]
6. Talk Timing
Maximum talk time available in a call
[90]
Table 2
Item
Descriptions
Factory Set
1. Ring Numbers
To set the monitor coded 0099 as local Switchboard, so when
the user does
”Call Switchboard ” on the monitor, the call will be
transferred to the 0099 monitor
[0]
Not
activated
2. Name List Mode
Reserved
3. Local IM as GU
To set the monitor coded 0099 as local Switchboard, so when
the user does
”Call Switchboard ” on the monitor, the call will be
transferred to the 0099 monitor
[0]
Not
activated
4. Multi IM Mode
To set the code rule when there are extended monitors in the
one apartment
[0]
Default
rule
5. Room Table Valid
To use the room table to call the monitor when room table is
downloaded to the door station through ST-Config
[0]
Not
activated
6. Room Table Only
Reserved
Summary of Contents for CAT-5 wired