![XtendLan CAT-5 wired Technical Manual Download Page 31](http://html1.mh-extra.com/html/xtendlan/cat-5-wired/cat-5-wired_technical-manual_3710370031.webp)
Page 27
ER
R
O
R
IN
U
SE
LI
N
K
PO
W
ER
T
/R
-
T
/R
+
•
JWP:
Power input. P+, positive 24V; P-,
negative.
•
JWB (IN1, IN2, IN3, IN4):
Connected to
JWP
PA S1
E RROR
P- P+ P- P+ PA S1
ON
DIP
1 2 3 4 5 6
LINK
RS-4 8 5
door stations (Max.4).
•
PA:
Test button. Press PA, the IN-USE
indicator will light, and then start to
monitor door station connected circu-
lar with click of relay.
•
S1:
DIP Switch function setting, refer to
DIP switch setting.
C5-MDS
I N-USE
P O WER
•
SW1:
Always set to the 2V, 2A position.
•
JTAG:
update port. Connected to PC to
update the firmware of C5-MDS
JWB( IN4 ) JWB( IN3 ) JWB( IN2 ) JWB( IN1 )
JWB( O UT)
JWB(I N4) JWB(IN3) JWB(IN2) JWB(IN1)
JWB(OUT)
•
RS-485:
PC port. Used to update the firmware of C5-MDS.
Specification
•
Power input: DC 24V
•
Standby Current: 50mA
•
Working Current: 80mA
•
Connection Port: RJ45
•
Working temperature: -10
0
C ~ +40
0
C
•
Dimension: 140*150*60 mm
2.3.4.6
Picture Memory Controller: C5-IMC
C5-ICM is independent picture memory controller for CAT5 system. When visitor call the monitor,
the C5-IMC will start to capture picture and save it, the resident can view the picture on the
indoor monitor.
•
Picture playing is continuous and the switch time can be set by DIP switch
•
Up to 800 pictures can be saved
Parts and functions
•
S201:
DIP switch
•
PA201:
Capture picture in normal status, for DIP test in test status
•
PA202:
Play picture in normal status, for EEPROM test in test status
•
PA203:
Exit in normal status, for monitor communication in test status
Summary of Contents for CAT-5 wired
Page 1: ...CAT 5 video intercom system Technical guide...
Page 10: ......