![XtendLan CAT-5 wired Technical Manual Download Page 60](http://html1.mh-extra.com/html/xtendlan/cat-5-wired/cat-5-wired_technical-manual_3710370060.webp)
Page 56
Chapter 4
CAT5 System Settings
PS5
E
B
+
EB
-
N
.O
L
K
+
LK
-
+
1
2
V
§
4.2 Lock Connection
4.2.1
Lock Type
The door station can connect two kinds of lock:
The power-on to unlock type: The lock stays locked when there is no power, and unlocks once it
gets the power from the power supply.
The power-off to unlock type: The lock stays locked when there is power feeding it , and unlocks
once the power is cut off.
4.2.2
Connection Diagram
The lock can get power from the door station directly or from the additional power supply, we call
these two internal power supply and external power supply separately.
4.2.2.1
Door Lock Controlled with Internal Power
To C5-IPC or Distributor
+ -
AC
Connect N.O
and +12V pins
+ -
CN-LK
RF CARD
T/R- T/R+
3 2 1
CN1
CN2
Bus
1 2 3
J/KMB
JP-LK
4 5 6
7 8 9
*
0 #
Set to 2-3
Exit Button
Note:
DPC-
518ID
LOCK
1. Electronic lock of Power-on-to-unl ock ty pe should be used.
2. Working current of lock must be less than 250mA, and working v oltage must be DC12V
3. JP-LK must be set to 2-3 position, N.O. and 12V pins of CN-LK must be connected together.
4. Unlock Output(unlock mode) must be set to 0(By def ault)