17
Document MT1602P.A
© Xsens Technologies B.V.
MTi-600 series DK User Manual
4.6 Electrical specifications
Table 13: MTi-600 DEV power supply specifications
Min
Typ
Max
Unit
V
USB
4.5
5
5.5
V
V
ext
4.5
-
24
V
4.7 Absolute maximum ratings
Table 14: Absolute maximum ratings MTi-600 DEV
Parameter
Min
Max
Unit
Comments
Operating temperature
-40
+85
ºC
V
ext
-0.3
30
V
Power input on
External connector
or
DSUB9
connectors
V
USB
-0.3
6.0
V
USB power input
V
UART
-0.3
3.6
V
V
RS232/SYNC
-25
25
V
V
RS422
-15
15
V
V
CAN_DC
-58
58
V
Common mode voltage of CAN_H
and CAN_L with respect to ground
V
CAN_DIFF
-17
17
V
Differential voltage between
CAN_H and CAN_L
Acceleration
4
10,000
g
Any axis, unpowered, for 0.2 ms
ESD protection
5
±2000
V
Human body model
Stresses beyond those listed under
“Absolute Maximum Ratings” may cause permanent damage to the
device. These are stress ratings only. Functional operation of the device at these or any other conditions
beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
4
This is a mechanical shock (g) sensitive device. Proper handling is required to prevent damage to the part.
5
This is an ESD-sensitive device. Proper handling is required to prevent damage to the part.