6  

UM Temp74 PT100 Vio EN rev.1 19.05.2023 

Instrumental Characteristics 

Technical Data

Tool 

Temp74 PT100 Vio 

Probes 

PT100 (x4) 

Inputs 

4 x 3-pin connector 

Measuring range 

-200,0...+999,9 °C

Resolution 

0.01 °C (-99.99 to +99.99 °C) / 0.1 °C in the rest of the scale 

Accuracy 

± 

0.03 °C (-99.99 to +99.99 °C) / 

± 

0.1 in the rest of the scale 

Display 

TFT - 4" high definition 

Brightness and contrast management 

Manual and automatic with integrated sensor 

Sleep Mode 

Yes 

Auto power-off 

Yes, 20 minutes (can be deactivated) 

LED Indication 

Yes 

Reading stability indicator 

Yes Adjustable (Low-Nor-High) 

Reading Hold (HOLD) 

Yes 

MAX/MIN reading 

Yes 

Offset Adjustment 

Yes for each channel independently 

Internal memory 

200,000 data 

Data logger 

Manual - Automatic - Programmed 

Sampling 

1 min...99 hours 

Working conditions 

Temperature: 0...+60 °C / Humidity: <95% R.H. (non-condensing) 

Maximum altitude of use 

2000 m 

Dimensions 

185 x 85 x 45 mm 

Weight 

400 g 

Degree of protection 

IP 56 

Sound level during operation 

< 80 dB 

Power supply 

3 x 1.5V 'AA' alkaline 

Battery life 

> 550 hours

Reference Standards 

EMC 2014/30/EU / RoHS 2011/65/EU / EN 61326-1 

Description Instrument 

Display single channel

123456789

37,05 °C

12,2 °C

37,05 °C

min

max

Measuring channel 

Battery level 

Stability indicator 

Minimum value 

HOLD function active 

Date and time 

Measured value 

Sensor ID 

Maximum value 

Recorded Values 

Data logger 

Connection to PC 

Temperature

System

Summary of Contents for Temp74 PT100 Vio

Page 1: ...INSTRUCTION MANUAL Temp74 PT100...

Page 2: ...tilingual copy Espa ol Para reducir los gastos este manual ha sido impreso exclusivamente en italiano e ingl s Contacta tu distribuidor para recibir la copia digital multi idioma Deutsch Um umweltfreu...

Page 3: ...nstrumental Characteristics 6 Technical Data 6 Description Instrument 6 Display single channel 6 Multiview screen 7 Keyboard 7 Key Functions 8 LED 8 Installation 8 Supplied Components 8 Commissioning...

Page 4: ...ngs 14 Date and time 14 Units of Measurement 14 Language 14 Auto off 14 Sound 14 Password 15 Temperature measurement 15 Measure 15 MAX MIN function 15 HOLD function 15 Other functions 15 Automatic swi...

Page 5: ...ormation NOTE for useful product information Warning symbols Additional documents providing security information The following documents can provide the operator with additional information to work sa...

Page 6: ...mended to occasionally clean the instrument casing with a damp cloth and mild detergent This operation should be carried out with the instrument switched off and only by experienced and authorised per...

Page 7: ...MAX MIN reading Yes Offset Adjustment Yes for each channel independently Internal memory 200 000 data Data logger Manual Automatic Programmed Sampling 1 min 99 hours Working conditions Temperature 0 6...

Page 8: ...X and MIN values recorded Press for 3 seconds to activate and deactivate the HOLD function and to deactivate the MAX MIN recording function if active Directional key DOWN RM to scroll through menus an...

Page 9: ...he display brightness Only at this point do the buttons regain their function LED All instruments are equipped with a two colour LED red and green that provides the user with important information on...

Page 10: ...carrying case Only use the original carrying case to transport the instrument Contact your local distributor if you need to buy it back The inside of the case is shaped to accommodate the instrument...

Page 11: ...e below shows the Setup menu structure for the parameter for each programme the options the user can choose and the default value Description Options Factory Settings Sensor ID Probe 1 Probe 2 Probe 3...

Page 12: ...annels to be aligned to the reference channel Select our reference channel from the Setup menu Temp Settings Reference Probe and press to confirm In the Offset Probes menu select Align All The measure...

Page 13: ...the table above Note When the reset is complete the instrument returns to measurement mode and the parameters are reset to default settings Log Settings Menu TEMP Measurement Settings LOG Data logger...

Page 14: ...pendently once the set date and time is reached and will stop Note If recording takes place while there is a single channel measurement on the display data concerning only that channel will be saved I...

Page 15: ...er battery life Brightness Access this Setup menu to choose between three different display brightness levels Low Normal High Note Keeping the display at high brightness at all times negatively affect...

Page 16: ...appears on the display Always wait for the measurement to become stable Note If no temperature probe is connected the message CONNECT A PROBE appears When connecting or disconnecting probes the instru...

Page 17: ...corrected and the adjustment value with flashing cursor using the keys correct the value to Current Temperature to 0 0 C press to confirm and record the adjustment Note The adjustment affects the ent...

Page 18: ...e manufacturer will repair or replace defective components This guarantee applies only to the electronic part and does not apply if the product has been damaged misused exposed to radiation or corrosi...

Page 19: ...18 UM Temp74 PT100 Vio EN rev 1 19 05 2023 XS Instruments Via della Meccanica n 25 41012 Carpi MO ITALY Tel 39059 653274 Fax...

Reviews: