SFD1900
Low 16 bits of pulse default
speed
Only when speed=0, default
speed is used to transmit pulse.
Third set of
parameters
SFD1901
High 16 bits of pulse default
speed
SFD1902
Accelerating time of pulse
default speed
SFD1903
Decelerating time of pulse
default speed
SFD1904
Acc and Dec time of tween
SFD1905
Reserved
SFD1906
Low 16 bits of max speed
limiting
SFD1907
High 16 bits of max speed
limiting
SFD1908
Low 16 bits of starting speed
SFD1909
High 16 bits of starting speed
SFD1910
Low 16 bits of ending speed
SFD1911
High 16 bits of ending speed
SFD1912
Curve acceleration time (ms)
…
SFD1920
Low 16 bits of pulse default
speed
Only when speed=0, default
speed is used to transmit pulse.
Forth set of
parameters
SFD1921
High 16 bits of pulse default
speed
SFD1922
Accelerating time of pulse
default speed
SFD1923
Decelerating time of pulse
default speed
SFD1924
Acc and Dec time of tween
SFD1925
Reserved
SFD1926
Low 16 bits of max speed
limiting
SFD1927
High 16 bits of max speed
limiting
SFD1928
Low 16 bits of starting speed
SFD1929
High 16 bits of starting speed
SFD1930
Low 16 bits of ending speed
SFD1931
High 16 bits of ending speed
SFD1932
Curve acceleration time (ms)
…